X1 SERIES ELEVATOR CONTROLLER INSTALLATION & PROGRAMMING GUIDE | DIGITAL MONITORING PRODUCTS
12
Program the X1 Elevator Controller and Floors
1� Go to
System Information
�
2� Under
Elevators
, select the Add icon �
3� Enter the serial number of the elevator controller�
4� Enter a descriptive name for the elevator controller�
5� In
Floor Activation Time
, enter the number of seconds that the elevator controller relays
remain active after access granted� This is provided by the elevator service company and
varies by manufacturer�
6� In
Reader Protocol
, choose a protocol for the elevator controller readers: Wiegand or OSDP�
For OSDP readers, configure buzzer and LED options�
7� If using the onboard outputs, enter descriptive names in
Onboard Output 1 Name
and
Onboard Output 2 Name
� If not using the onboard outputs, leave the name fields blank�
8� Turn on other options as needed:
Additional Elevator Options:
•
Buzzer
(OSDP) allows the reader to beep when a card is read�
•
LED
(OSDP) allows the reader LED to turn on and operate the same as a Wiegand reader LED, lighting green when
the module relay activates� If disabled, the reader LED is turned off and does not operate in any condition�
•
Include in Lockdown
allows the elevator to be included when a lockdown is initiated�
•
Request To Exit
(REX) not typically used for elevator access�
9� When the first elevator control module populates, enter the name and address of the elevator
control module� The address is the number that the address rotary dial is set to�
10� Name up to 10 floor relays� If additional elevator control modules are being used, follow the
steps in
Add Additional Floors
�
11� Press
Save
�
Add Additional Floors
If additional elevator control modules are being used, follow the steps below� Otherwise skip to
Add
Card Formats
�
1� Under
Floors
, select the Add icon �
2� Enter the name and address of the elevator control module�
3� Name up to 10 floor relays�
4� Press
Save
�
4