background image

Digital Monitoring Products, Inc  |  7000 Series Installation and Programming Guide  

42

FCC INFORMATION

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

1. 

This device may not cause harmful interference, and

2. 

This device must accept any interference received, including interference that may cause 
undesired operation.

Changes or modifications made by the user and not expressly approved by the party responsible for 
compliance could void the user’s authority to operate the equipment.

Note

: This equipment has been tested and found to comply with the limits for a Class B digital 

device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable 
protection against harmful interference in a residential installation. This equipment generates, 
uses and can radiate radio frequency energy and, if not installed and used in accordance with 
the instructions, may cause harmful interference to radio communications. However, there is 
no guarantee that interference will not occur in a particular installation. If this equipment does 
cause harmful interference to radio or television reception, which can be determined by turning 
the equipment off and on, the user is encouraged to try to correct the interference by one or 
more of the following measures:

• 

Reorient or relocate the receiving antenna.

• 

Increase the separation between the equipment and receiver.

• 

Connect the equipment into an outlet on a circuit different from that to which the receiver is 
connected.

• 

Consult the dealer or an experienced radio/TV technician for help.

Содержание Thinline Aqualite 7000 Series

Страница 1: ...FRI 2 52 PM 1 2 3 4 5 6 7 8 9 0 CMD A C B D F E G I H J L K V X W S U T P R Q M O N Y Z ENTE R BACK INSTALLATION AND PROGRAMMING GUIDE 7000 Series ThinlineTM and AqualiteTM Keypad...

Страница 2: ......

Страница 3: ...re the 333 Suppressor 13 Program the Keypad 16 Keypad Options 16 Custom Card Format 20 Additional Programming 27 Test the Keypad 28 End User Training 30 Keypad Arming and Disarming 31 Keypad Access Co...

Страница 4: ......

Страница 5: ...keyboard and DMP logo Internal speaker Red keyboard lighting in alarm conditions Simple harness connection to 4 wire keypad bus Optional backboxes for conduit or wall mount applications Models 7070 A...

Страница 6: ...ATURES FRI 2 52 PM 1 2 3 4 5 6 7 8 9 0 CMD A C B D F E G I H J L K V X W S U T P R Q M O N Y Z ENTE R BACK Armed Power LEDs Proximity Credential Reader and Backlit Logo Keypad Display Status List Sele...

Страница 7: ...nc 3 ABC SECURITY FRI 2 52 PM 1 2 3 4 5 6 7 8 Power LED Armed LED 32 Character Display Select Keys Command Back Arrow 9 0 CMD A C B D F E G I H J L K V X W S U T P R Q M O N Y Z ENTE R BACK Proximity...

Страница 8: ...umber pad 3 Identify the Select Key for the character and press that select key on the keypad Press that select key again for the lowercase letter Latin characters only 4 When the desired character di...

Страница 9: ...t keys Zone 39 Device Address 7 0 Panic Keys All keypads allow the user to initiate a panic alarm by pressing the 7 and 0 zero keys at the same time for one half 1 2 second Enable the 7 0 Panic functi...

Страница 10: ...y is pressed If no keys are pressed and the speaker has not sounded for 30 seconds the user selected brightness level restores Internal Speaker Tone Adjust the keypad internal speaker tone At SET TONE...

Страница 11: ...ircuit board and components and the base To separate the keypad cover from the base insert a flathead screwdriver into one of the slots on the bottom of the keypad and gently lift the screwdriver upwa...

Страница 12: ...t to the keypad bus The remaining eight wires are for the four zone inputs four wires for each zone Models 7073 A and 7173 Supplied with a 5 wire output reader harness and a 12 wire data bus zone harn...

Страница 13: ...e from the power supply negative terminal to the panel common ground terminal 3 Connect all keypad power 12 VDC wires to the power supply positive terminal Do not connect the power supply positive ter...

Страница 14: ...Black Ground Green Receive Data Yellow Send Data Red Keypad Power Zone 4 Zone 3 Zone 2 Zone 1 ExternalReader Door Strike 7073 7073A 7173 Keypads All Keypads Zones 1 4 7070 7070A 7073 7073A 7170 7173...

Страница 15: ...imity credentials are not compatible with DMP proximity keypads Test the intended proximity credentials with the application before installation DMP does not guarantee compatibility with credentials n...

Страница 16: ...e Common Violet Door Strike Normally Closed Black Ground Green Receive Data Yellow Send Data Red Keypad Power Yellow White Zone 4 Orange White Zone 3 REX Red White Zone 2 Brown White Zone 1 7 0 Panic...

Страница 17: ...N C gray common COM and orange normally open N O allow you to connect devices to the relay The Form C relay draws up to 15 mA of current and the contacts are rated for 1 Amp at 30 VDC maximum WIRE TH...

Страница 18: ...Programming Guide 14 Model 333 Supressor Common Magnetic Door Lock DMP 505 Power Supply Normally Open Green White D0 White D1 Orange N O Gray C Violet N C N O C N C Normally Closed Keypad 5 Wire Harn...

Страница 19: ...cted you can provide a programmed bypass time by connecting its contact to Zone 2 white red pair on the keypad and enabling the bypass feature Door contacts may be N C or N O Zone 3 Request to Exit Yo...

Страница 20: ...or Unsupervised mode change the default keypad message selectively enable the 2 button Panic keys Bypass REX and set entry card options All programming options display on all keypads However actual o...

Страница 21: ...e of up to 16 characters to appear at the top of the keypad display Press any select key enter a new message and press CMD Arm Panic Keys Use this option to configure the select keys as two button pan...

Страница 22: ...he user has five seconds to open the door connected to zone 2 The zone is then bypassed for the programmed time or until the contact restores to normal Ten seconds prior to the expiration of the bypas...

Страница 23: ...3 Enter the number of REX seconds to elapse Range is 5 250 seconds Press any select key to clear the keypad display and enter the number of seconds The default is 5 ALL NO YES 7063 A 7073 A 7163 7173...

Страница 24: ...g The menu advances to REQUIRE SITE Select CUSTOM to disable DMP format and program slots 1 8 as needed The menu advances to FORMAT NO Select ANY to allow all Wiegand card reads to activate the door s...

Страница 25: ...format that is programmed in slot 1 To restrict card reads to specific formats only program slots 2 8 See Public Card Formats for some publicly available card formats that can be used with the keypad...

Страница 26: ...een 1 255 to equal the number of bits Default is 26 bits An access card contains data bits for a site code user code and start stop parity bits The starting position location and code length must be d...

Страница 27: ...ss select area 2 to clear the user code position and enter a number between 0 255 Press CMD to save Default is 9 Press select area 4 to clear the user code length and enter a number between 16 64 Pres...

Страница 28: ...D Number of User Code Digits The keypad recognizes user codes from 4 12 digits long Press any top row select key or area to enter a user code digit length This number must match the user code number l...

Страница 29: ...on but turns off at the end of the door strike timer Press the second select key or area to choose SITE Accept Site Code Door access is granted when the Wiegand site code string received matches any s...

Страница 30: ...to change the language options Press select key 1 to select English Press select key 2 to select Spanish Press select key 3 to select French Press select key 4 to select Dutch Press CMD to advance th...

Страница 31: ...eader can be connected and will be compatible with 13 56 MHz proximity credentials For a list of publicly supported card formats see Public Card Formats Note Some proximity credentials are not compati...

Страница 32: ...e keypad lights all display segments and illuminates the keyboard in red The display backlighting then changes to green The keypad alternates between these two states for approximately two minutes Pre...

Страница 33: ...e test displays on the other keypads but is not operational Input Wiegand 7063 A 7073 A 7163 7173 This option tests the internal and external reader input from proximity credentials The display shows...

Страница 34: ...eypad Arming and Disarming Keypad Access Control Keypad Entry Delay All of the examples displayed assume that CLOSING CODE is YES in panel programming Figures 9 through 12 show the user presenting a c...

Страница 35: ...ENTER CODE The user presents their card to the reader Once validated by the system all areas assigned to that code arm or disarm automatically and the 7073 A and 7173 keypad door strike relay activat...

Страница 36: ...7073 A and 7173 keypads the Door Strike relay then activates Home Away System Arming and Disarming Present your card to the reader If the system is armed once the card is validated all areas are disar...

Страница 37: ...oor Strike relay activates Home Away systems only activate the 7073 A and 7173 Door Strike relay when arming and disarming ABC SECURITY MON 10 20 AM While the keypad displays the Status List present y...

Страница 38: ...TER CODE Present your card to the reader Once validated the system disarms all areas accessible by you and activates the 7073 7073A 7173 Door Strike relay Area systems provide a delay to allow selecte...

Страница 39: ...ne circuit length of wire is 2 500 feet regardless of the wire gauge This distance can be in the form of one long wire run or multiple branches with all wiring totaling no more than 2 500 feet As wire...

Страница 40: ...NORMAL STANDBY CURRENT ALARM CURRENT FOUR ZONES INTERNAL PROX READER WIEGAND INPUT INTERNAL DOOR STRIKE RELAY 7060 A 7160 72 mA 87 mA 7063 A 7163 85 mA 100 mA X 7070 A 7170 72 mA 1 6 mA per active zo...

Страница 41: ...EGAND CODE LENGTH SITE CODE POSITION SITE CODE LENGTH USER CODE POSITION USER CODE LENGTH USER CODE DIGITS H10301 26 BIT 26 1 8 9 16 5 H10302 37 BIT W FAC 37 1 16 17 19 6 H10304 37 BIT W O FAC 37 0 0...

Страница 42: ...ROX PROXIMITY READER MX 5375 MAXIPROX PROXIMITY READER PP 6005B PROXPOINT PLUS PROXIMITY READER PP 5355 PROXPRO PROXIMITY READER WITH KEYPAD PR 5455 PROXPRO II PROXIMITY READER TL 5395 THINLINE II PRO...

Страница 43: ...3 FARPOINTE SMARTCARD READER DELTA5 FARPOINTE SMARTCARD READER DELTA5 3 FARPOINTE SMARTCARD READER DELTA6 4 FARPOINTE SMARTCARD READER 13 56 MHZ SMARTCARD CREDENTIALS DC1 1 FARPOINTE CLAMSHELL SMARTCA...

Страница 44: ...ULC listed applications Specifications Operating Voltage 12 VDC Thinline Aqualite Dimensions 7 W x 5 25 H x 0 5 D Compatibility All keypads are compatible with all DMP panels ACCESSORIES Backboxes 695...

Страница 45: ...ry UL Listed ANSI UL 294 Access Control System Units Level I Destructive Attack and Line Security Level IV Endurance and Standby Power ANSI UL 365 Police Connected Burglar ANSI UL 609 Local Burglar AN...

Страница 46: ...ed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in acc...

Страница 47: ...l utilisateur de l appareil doit accepter tout brouillage radio lectrique subi m me si le brouillage est susceptible d en compromettre le fonctionnement This system has been evaluated for RF Exposure...

Страница 48: ...LT 0883 19314 1 04 2019 Digital Monitoring Products Inc...

Отзывы: