Digital Monitoring Products, Inc | 7000 Series Installation and Programming Guide
16
PROGRAM THE KEYPAD
Keypad Options and Keypad Diagnostic menus allow install and service technicians to
configure and test keypad operation. To access the installer options:
1.
Hold down the back arrow and
CMD
keys for two seconds.
2. At
SET
BRIGHTNESS
, enter
3577
(INST) and press
CMD
.
The display changes to
KPD
OPT
KPD
DIAG
and
STOP
. The Keypad Options menu allows
you to set the keypad address, select Supervised or Unsupervised mode, change the
default keypad message, selectively enable the 2-button Panic keys, Bypass, REX, and set
entry card options.
All programming options display on all keypads. However, actual operation for some
programming options is restricted to the appropriate model.
KEYPAD OPTIONS
Keypad Options
To program keypad options, press
KPD OPT
.
Current Keypad Address
Set the current keypad address from 01 to 08 for
XT30/XT50/XR150 Series panels or 01 to 16 for XR550 Series
panels. The default address is 01. To change the current
address, press any select key and enter the new address. Do
not enter a leading zero for addresses 01 to 09.
KPD
KPD
OPT
DIAG
STOP
CURRENT KEYPAD
ADDRESS: 1