background image

Digital Monitoring Products 

693/

791/793 Installation Sheet

6

Exiting the Installer Options

When done, press the COMMAND key once to return to the Installer Options screen.  Press the Select key under STOP 
to exit the Installer Options function.

Programming Cards into the System

From the User Menu, select USER CODES?.  Choose ADD.  At the ENTER CODE: - display, present the user card to the 
reader.  The keypad works by reading the 4 or 5-digit user code from the data sent by the access control reader.  For 
more information, refer to the panel user’s guide section on adding, deleting, and changing user codes.

Additional Power Supply

If the current draw for all keypads exceeds the panel output, you can provide additional current by adding a Model 
505-12 auxiliary power supply.  Connect all keypad common wires to the negative terminal of the power supply.  Run 
a jumper wire from the power supply negative terminal to the panel common terminal.  Connect all keypad power 
(+12 VDC) wires to the power supply positive terminal.  Do NOT connect the power supply positive terminal to any 
panel terminal.  Refer to the 504-24 and 505-12 Power Supply Installation Guide (LT-0453) for more information. 

701 and 793 Door Strike Relay Speci

Þ

 cations

The Easy Entry keypads provide one internal Form C single pole, double throw (SPDT) relay for controlling door 
strikes or magnetic locks.  Three wires on the 5-wire harness, Violet (N/C), Gray (Com), and Orange (N/O), allow you 
to connect devices to the relay.
The Form C relay draws up to 30mA of current and its contacts are rated for 1 Amp at 24 VDC.

Access the User Menu

You can also use a card reader to access the User Menu.  When the MENU?  NO YES displays, present your proximity 
card to the reader.

Door Strike Relay Operation

As soon as the user code sent from the reader has been veri

Þ

 ed by the panel, the keypad Door Strike relay activates 

for 

Þ

 ve seconds.  During this time, the access door connected to zone 2 must be opened to start the 40-second 

entry/exit timer and zone soft shunt.  See the timeline shown below.

Note

: The 5-second delay length is programmable when the keypad is used on an XR200-485 or XR500/XR500N.

5 Second

Strike

40-Second "Soft-Shunt"
and entry/exit timer.

At 30 seconds,
the keypad beeps
if door is still open.

End of 
timer.

40

Seconds

A zone fault is indicated
if door is still open.

Figure 7: Door Strike Relay operation time line

User’s Guide

There are three different operating modes: Door Strike, 
Arming and Disarming, and Entry Delay. All of the 
examples below assume that CLOSING CODE is YES in panel 
programming.

Door Strike

Area and All/Perimeter Door Strike.  From the Status List, 
present your card to the reader. Once the system validates 
the card, the Door Strike relay activates. See Door Strike 
Relay Operation above. Home/Away systems only activate 
the Door Strike relay when arming and disarming.

         

 ABC 

SECURITY

ARM  

DISARM

While the keypad is in
the Status List, present
your access card.

The relay activates for 5 seconds during
which time you can open the door.
Once you open the door, you have 40
seconds to exit and close the door 
before the Zone 2 Soft-Shunt expires.

Figure 8: Present access card

Содержание Easy Entry 693

Страница 1: ...s The harness connections and color codes are shown in Figure 1 Surface and Backbox Mounting Holes Combined 4 square adn 3 gang switch box Mounting Holes Keypad Base Back Surface and Backbox Mounting Holes 1K EOL 1K EOL 1K EOL 1K EOL Green White Connect Reader Data 0 White Connect Reader Data 1 Orange Door Strike Normally Open Gray Door Strike Common Violet Door Strike Normally Closed Yellow White...

Страница 2: ...l sends an alarm report to the central station with the following zone numbers 19 Panic 29 non medical Emergency 39 Fire You must program the Panic key function in order to use the Panic keys See Programming Instructions later in this document Install the supplied icon label below the top row of Select keys Top Row Select Keys Police Emergency Fire Label shows Icons only Figure 3 Panic key label p...

Страница 3: ...data wire from the reader Data 0 to the Green White wire on the 5 wire keypad harness 1K EOL 1K EOL 1K EOL 1K EOL Green White Connect Reader Data 0 White Connect Reader Data 1 Orange Door Strike Normally Open Gray Door Strike Common Violet Door Strike Normally Closed Yellow White White Yellow Orange White White Orange Red White White Red Brown White White Brown Black Data Bus 693 Ground 791 793 Gr...

Страница 4: ...he factory default address is set at 01 To change the current address press any Select key and then enter the new address using the appropriate number keys on the keyboard It is not necessary to enter a leading zero for addresses 01 to 09 Select Supervised or Unsupervised KEYPAD MODE You can conÞgure the keypad for either supervised or unsupervised operation Supervise keypads that have zones conne...

Страница 5: ... user codes ALL NO YES DELAY 2 Select the number of seconds the keypad should wait when an area system displays ALL NO YES during arming disarming or a HOME SLEEP AWAY system waits during arming only If No or YES or HOME SLEEP or AWAY is not pressed before the delay expires the keypad automatically selects the YES or the AWAY key Select zero 0 for no delay The delay can be one to nine 1 9 seconds ...

Страница 6: ...The Form C relay draws up to 30mA of current and its contacts are rated for 1 Amp at 24 VDC Access the User Menu You can also use a card reader to access the User Menu When the MENU NO YES displays present your proximity card to the reader Door Strike Relay Operation As soon as the user code sent from the reader has been veriÞed by the panel the keypad Door Strike relay activates for Þve seconds D...

Страница 7: ...TER CODE Present your card to the reader Once validated by the system both areas arm or disarm automatically and the Door Strike relay activates Home Away system Arming and Disarming Present your card to the reader If the system is armed once the card is validated all areas are disarmed If the system is disarmed when you present your card once the card is validated all areas are armed in the AWAY ...

Страница 8: ... conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Changes or modiÞcations made by the user and not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment NOTE This equipment has been tested and found to comply with...

Отзывы: