736V V‑PLEX MODULE

Specifications

Primary Power 

12 VDC

Current Draw 

45 mA

Dimensions 

2” H X 3.5” W X 0.5 D

Accessories

Model 330 

Dual‑Ended 4‑Wire Harness

Compatibility

XR150/XR550 Series Panels with Firmware Version 191 

(7/2/19) or higher

V‑Plex Devices

DT7500SN V‑Plex DUAL TEC Motion Sensor
5193SD/5193SDT One Piece Photoelectric Smoke Detector
4959SN Addressable Overhead Door Contact
4193SN/4293SN Micro‑miniature V‑Plex Adapter
IS2500SN V‑Plex PIR Motion Sensor
269SN V‑Plex Holdup Switch
4939SN Addressable Surface Mount Contact
4190SN Two Zone Remote Point Module
FG1625SN FlexGuard®
419SN‑WH Recessed Door Contact
4101SN Relay Module
VPLEX‑VSI V‑Plex Short Isolator
4208U Universal Eight Zone Remote Point Module

ADDITIONAL INFORMATION

Diagnostic LEDs

The module has two onboard LEDs. The green LED indicates connection to the LX‑Bus and should flash once every two 

seconds. The yellow LED indicates that polling loop devices are communicating with the module.

Reboot the 736V

Before rebooting the module, remove the jumper from the Write Ena/Clear pins. To reboot, turn the last LX‑Bus output 

off, then back on. For example, if the module is connected to LX500, turn output 599 on then off.

Reuse a 736V V‑Plex Module

Before reusing a 736V, disconnect all zones. Delete all data in the module by placing the jumper across both 

Write Ena/Clear pins and powering up the panel.

5

Perform a Burglary Zone Walk Test to confirm that all of the devices are properly configured and 

communicating with the panel.

1.  Reset the panel.

2.  At a keypad, enter 

8144

 (WALK) and select 

BG

.

3.  Trip each zone on the system for 1 to 2 seconds. The keypad will annunciate each time a zone is tripped 

and display the number of zones successfully tripped.

4.  Press the fourth select area or key to end the Walk Test.

TEST THE 736V