Digital Monitoring Products, Inc. | 734N Series Installation and Programming Guide
1
Annunciators
An onboard programmable piezo provides
local annunciation at the module. You can
also connect a variety of switched ground
annunciators to the module for remote
annunciation.
Indicator LEDs
734N Series modules provide three
indicator LEDs:
• RELAY (red) turns on for the same
duration as the door strike relay.
• WIEGAND (yellow) turns on for one
second to indicate receipt of valid input.
• DATA (green) indicates that the module
is communicating with the panel.
The 734N and 734N‑POE Access Control Modules allow you to add IP network access
control capability to XR150/XR550 Series panels using proximity, credential, or
mag‑stripe card readers. The modules also allow you to use the powerful built‑in access
control capability of DMP Panels.
Power Supply
734N Series modules operate at
12/24 VDC from the power supply
supporting a door’s magnetic lock or
door‑strike. The 734N‑POE can also be
powered from POE.
Warning:
To avoid the risk of
equipment damage, do not exceed
750 mA total output current for
zones connected to the module.
Zone Terminals
Four input zones are provided to allow
connection of nearby burglary devices.
ABOUT THE 734N SERIES