Wire the Access Control Lock
The 734INT provides a Form C (SPDT) relay for controlling locks and other
electronically‑controlled barriers. The three relay terminals marked NO C NC allow
you to connect the device wiring to the relay for module control.
Use an additional power supply to power magnetic locks and door strikes. See
Figure 3 and Figure 4 for typical magnetic lock and door strike wiring.
The Form C relay draws up to 35 mA of current and contacts are rated for 10 Amps
(resistive) at 12/24 VDC. When connecting multiple locks to the Form C relay, the
total current for all locks cannot exceed 10 Amps. If the total current for all locks
exceeds 10 Amps, problems may arise and an isolation relay may be needed. Refer
to “Isolation Relay (optional)” for more information.
2
Model 333
Suppressor
–
+
12/24 VDC
Power Supply
Normally Closed
Magnetic Door
Lock
Mag lock positive
to Terminal NC
Power supply positive
to Terminal C
Mag lock negative to
power supply negative
Figure 3: Typical Magnetic Lock Wiring
Model 333
Suppressor
–
+
12/24 VDC
Power Supply
Normally Open
Door strike positive
to Terminal NO
Power supply positive
to Terminal C
Door strike negative to
power supply negative
DC Door Strike
Figure 4: Typical Door Strike Wiring