Digital Monitoring Products, Inc. | 734INT Installation and Programming Guide
21
ACCESS OPTIONS
Activate Zone 2 Bypass
Select
YES
to activate the zone 2 bypass operation. Selecting
NO
allows standard zone operation on zone 2. The default is
NO
.
If the door being released by the 734INT module is protected
(contact installed), a programmable bypass entry/exit timer
can be provided by connecting its contact wiring to module
zone 2. When the onboard Form C relay activates and
the user opens the door connected to zone 2, the zone is
delayed for the number of seconds programmed in
ZONE
2 BYPASS TIME
allowing the user to enter/exit during an
armed period.
If zone 2 does not restore (door closed) within the
programmed time, the piezo sounds every other second
during the last ten seconds. If zone 2 restores prior to the
end of the programmed time, the piezo silences. If the zone
does not restore before the programmed time, the 734INT
ends the bypass and indicates the open or short zone
condition to the panel.
ACTIVATE ZONE 2
BYPASS?
NO
YES