734 Installation and Programming Guide | Digital Monitoring Products
13
OSDP Secure Key
The secure key is programmed into the OSDP reader and is used to establish 128-bit
AES encrypted two-way communication between the reader and module.
Record this key and store it in a secure location away from the module and reader.
After the reader is bonded to the module, the secure key cannot be changed in the
reader or retrieved from 734 programming. Replacement modules can be bonded to
any compatible reader with the reader’s secure key.
Caution:
OSDP readers can only be programmed locally from the module with a
keypad. To properly bond the reader to the module, the 734 must be initialized
and the reader must be new or factory reset. After programming is complete
and the keypad is disconnected, the reader is bonded to the module and cannot
be reprogrammed with a different secure key until it is factory reset by the
manufacturer.
Enter a secure key up to 16 alphanumeric characters. These characters are visible until
CMD
is pressed.
Activate Zone 2 Bypass
Select
YES
to activate the zone 2 bypass operation. Selecting
NO
allows standard
zone operation on zone 2. The default is
NO
.
If the door being released by the 734 module is protected (contact installed), a
programmable bypass entry/exit timer can be provided by connecting its contact
wiring to module zone 2. When the onboard Form C relay activates and the user
opens the door connected to zone 2, the zone is delayed for the number of seconds
programmed in
ZONE 2 BYPASS TIME
allowing the user to enter/exit during an armed
period.
If zone 2 does not restore (door closed) within the programmed time, the piezo
sounds every other second during the last ten seconds. If zone 2 restores prior to the
end of the programmed time, the piezo silences. If the zone does not restore before
the programmed time, the 734 ends the bypass and indicates the open or short zone
condition to the panel.
Zone 2 Bypass Time
Enter the number of seconds to elapse before the bypass timer expires. The range
is 20-250 seconds. Press any select key or area to enter the number of seconds. The
default is
40
seconds. Figure 12 shows how the bypass option works.
SECURE KEY
SECURE KEY
****************
ACTIVATE ZONE 2
BYPASS?
NO
YES
ZONE 2 BYPASS
TIME:
40
5-Second
Strike
40-Second Zone 2
Bypass Entry/Exit Timer
10 seconds before
the bypass time expires,
the device beeps if
the door is still open.
End of
Timer
40
Seconds
A zone open/short is
indicated if the door
remains open.
Figure 12: Zone 2 Bypass Timeline