Zone 2 Bypass Time
Enter the number of bypass seconds to elapse before the
bypass timer expires. Range is from 20-250 seconds. Press
any select key to clear the keypad display and enter the
number of seconds. Default is
40
seconds.
Relock on Zone 2 Change
Select
NO
(default) to leave the relay on when Zone 2
changes to an open or short condition during bypass.
Select
YES
to turn the relay off when Zone 2 changes to
open or short during bypass.
Activate Zone 3 Exit
Select
YES
to activate the Zone 3 Request to Exit (REX)
option. Select
NO
(default) to allow standard zone operation
on Zone 3. Connect a motion sensing device or a mechanical
switch to Zone 3 to provide REX capability to the system.
When Zone 3 shorts, the on-board Form C relay activates for
the programmed number of seconds (see Zone 3 REX Strike
Time). During this time, the user can open the protected
door to start the programmed Zone 2 bypass entry/exit
timer. After the programmed number of seconds, the relay
restores the door to its locked state.
ZONE 2 BYPASS
TIME:
40
RELOCK ZONE 2
CHANGE:
NO
YES
ACTIVATE ZONE 3
EXIT:
NO
YES