DMMetering PRO-1250 Series Скачать руководство пользователя страница 7

®

   

2007

 

             

 

 
1/2       

Ia IN/OUT             

3/4           

Ib IN/OUT 

5/6                  Ic IN/OUT             
7           

Neutral 

 
8 and 9    

Test pulse output contact 

 
 

                            B. CT series 

   

         

                                 

 

1/2   

   

Ia IN/OUT             

3/4             

Ib IN/OUT 

5/6                      Ic IN/OUT           
18/17/16  

Phase A/B/C 

15 

 

 

Neutral 

 
8 and 9     

Test pulse output contact 

 

1.9    Operating 

 
 

Consumption indication 

On the PRO-1250 SERIES’S front panel, there are four LED, in which three LED are for 

three phase voltage and another one for impulse. 

 

 

Reading the meter

 

The PRO-1250A series energy meter is equipped with a 5+1 register. Five integers are 

marked with black color and one decimal is marked with red. The PRO-1250D series 
energy  meter  is  equipped  with  5+2  LCD  display  which  is  used  as  recording 
consumption and can’t be reset to zero. The reading accuracy is 1/100 kWh. 

 

Pulse output 

PRO-1250 series DIN rail energy meter is equipped with a pulse output which is fully 
separated from the inside circuit. That generates pulses in proportion to the measured 
energy. They are test pulse output (pins 8 & 9). Usually, the test pulse output is used 
as testing accuracy or reading purpose in close quarters.   
The test pulse output is a polarity dependant, passive transistor output requiring an 
external  voltage  source  for  correct  operation.  For  this  external  voltage  source,  the 

Содержание PRO-1250 Series

Страница 1: ...se four wire energy meter 1 1 Safety instruction 1 2 Foreword 1 3 Performance criteria 1 4 Specifications 1 5 Basic errors 1 6 Description 1 7 Dimensions 1 8 Installation 1 9 Operating 1 10 Troublesho...

Страница 2: ...ground and label devices systems and circuits according to safety and Regulatory standards Use for the intended purpose The equipment device module may only be used for the application cases specified...

Страница 3: ...member of the Inepro Group The other names appearing in this manual may be trade names the use of these names by third parties for their own purposes may infringe the rights of the owners 1 2 Forewor...

Страница 4: ...d 6KV 1 2 S waveform Basic current Ib CT version 1A Direct version 10A Maximum rated current Imax CT version 5A Direct version 100A Operational current range 0 4 Ib Imax Over current withstand 30Imax...

Страница 5: ...ription A Front panel B Cover C Base D Security hasp Material Front panel PC inflammable retarding Cover ABS inflammable retarding Base ABS inflammable retarding 1 7 Dimensions Height 130 mm Width 126...

Страница 6: ...meter has to be installed in a protection box when placed in dangerous or dusty environment The meter can be installed and used after being tested and sealed with a letter press printing The meter ca...

Страница 7: ...color and one decimal is marked with red The PRO 1250D series energy meter is equipped with 5 2 LCD display which is used as recording consumption and can t be reset to zero The reading accuracy is 1...

Страница 8: ...ank wire or other material as you will have the chance of an electricity shock and a possible chance for health damage Turn off and lock out all power supplying the energy meter and the equipment to w...

Страница 9: ...or L2 or L3 when power supply is input Reinstall terminal screws on the 1 2 3 4 5 6 and 7 Make sure all screws are fixed Than there should be a 230V 50Hz AC voltage between the terminal screws on the...

Страница 10: ...is is why it seems like the meter won t count Please contact your technical supporter to replace this meter No test pulse output Is DC power supply connected to the meter Is the connecting correct May...

Отзывы: