Operation

Inspect pump, hoses, couplers, and fittings for wear or 

damage. Replace worn, damaged, or missing components 

with DMC replacement parts. Worn or damaged compo-

nents can fail, resulting in injury.
Failure to observe this warning could result in severe injury 

or death.

Electric shock hazard:
This tool is not insulated. When using 

this unit near energized electrical 

lines, use proper personal protective 

equipment.
Failure to observe this warning could 

result in severe injury or death.

Wear eye protection when operating or 

servicing this tool. 
Failure to wear eye protection could 

result in serious eye injury from flying 

debris or hydraulic oil. 

Cutting hazard:
•  Remove battery before changing dies, 

adapters, or jaws.

•  Keep hands away from the head when 

in operation.

Failure to observe these warnings could 

result in severe injury or death.

Skin injection hazard:
•  Do not use hands to check for leaks.
•  Depressurize hydraulic system before 

servicing or disconnecting the hose.

High pressure oil easily punctures skin, 

causing serious injury, gangrene, or death. 

If injured, seek medical help immediately 

to remove oil.

Electric shock hazard:  The owner of this tool must be 

certain that all users of this tool are trained in the applicable 

safety codes and  standards as well as in the safe use of this 

tool and its accessories.
Failure to observe this warning could result in severe injury 

or death.

•  Do not use this tool for continuous use. After 

100 cycles, allow the tool to cool for 15 minutes.

•  Do not secure this tool in a vise. This tool is designed 

for hand-held operation.

•  Use this tool for the manufacturer’s intended purpose 

only.

Failure to observe these precautions may result in injury 

or property damage.

Procedure for depressurizing the hydraulic system:
1.  Disconnect the pump from the power source.
2.  Press down on the manual release shaft and allow the 

ram to retract fully.

3.  Disconnect the hose slowly to release any trapped 

pressure.

Charging the Battery
Read the instructions supplied with the battery charger.

Содержание HPU13M

Страница 1: ...uctions and safety information in this manual before operating or servicing this tool HPU13M Battery powered Pump HPU13M DS REV A 2014 DANIELS MANUFACTURING CORP ALL RIGHTS RESERVED 526 Thorpe Rd Orla...

Страница 2: ...ards and unsafe practices related to the use of this tool Observe all of the safety information provided Purpose of this Manual This manual is intended to familiarize all personnel with the safe opera...

Страница 3: ...s manual before operating or servicing this tool Failure to observe this warning will result in severe injury or death Do not connect the pump to any system or system compo nent other than those suppl...

Страница 4: ...protection when using this tool Failure to wear eye protection could result in serious eye injury from flying debris or hydraulic oil Inspect pump hoses couplers and fittings for wear or damage Replac...

Страница 5: ...ry or property damage Do not allow anything to contact the battery terminals Do not immerse the batteries in liquid Liquid may create a short circuit and damage the battery If batter ies are immersed...

Страница 6: ...eservoir Capacity 0 80 qt 0 76 l Maximum Operating Pressure 10 000 psi 700 bar Operating Temperature Range 10 F to 104 F 12 C to 40 C Dual Stage Pumping Action Rapid Advance 0 9 l min At Full Pressure...

Страница 7: ...all positions without any oil leakages This tool is equipped with a circuit board incorporating several important features to inform the user about the current status of the unit Before operating the...

Страница 8: ...injury or death Skin injection hazard Do not use hands to check for leaks Depressurize hydraulic system before servicing or disconnecting the hose High pressure oil easily punctures skin causing serio...

Страница 9: ...sure has not been reached while motor was running Flashing light and audible alert for 1 second after cycle Error Required crimping pressure has not been reached Operator has interrupted crimping cycl...

Страница 10: ...n severe injury or death Relief valve adjustments must be done by an authorized service center Daily Before use 1 Inspect the tool for wear or damage such as cracks gouges or chips 2 Inspect the tool...

Страница 11: ...Start pump and hold retract button simultaneously Run for approximately 10 seconds and then attempt to cut If unsuc cessful return tool to DMC Cold oil Start pump and hold retract button simultaneous...

Страница 12: ...limited to the free correction or at DMC s option the refund of the purchase price of any such product which proves defective in normal service within ninety 90 days after delivery to the first user p...