HCE136C
BATTERY POWERED CRIMP TOOL
DATASHEET
________________________________________________________________________________________________
HCE136C-DS
©2022 Daniels Manufacturing Corp., All Rights Reserved Page 6 of 7
REV. A
6/14/2022
Daniels Manufacturing Corporation
526 Thorpe Road, Orlando, FL 32824 USA
Phone: 407-855-6161 Fax: 407-855-6884 Email: [email protected]
Other conditions indicated by the charger LED
Flashing Red -Charger is overheated. Unplug the charger,
and allow it to cool down.
Flashing Red, with Flashing Green-This indicates a
defective battery.
Bluetooth Connectivity
This tool features Bluetooth connectivity for tool monitoring
via Klauke
i-press
®
software.
•
Exports all tool data, so you can check the tool
status.
•
In addition, i-press provides you with proof of quality
in the form of a project record.
i-press
®
app
•
Made easy – Your Next Generation tool connects to
the i-press
®
app via Bluetooth – you can now use the
comprehensive range of functions.
•
Everything under control – You can, for example,
display the last service date, the last five pressure
values, the device temperature or the number of
crimps you can still make with the connected tool.
•
Record, verify and archive – Once the project is
complete, you will receive an overview containing all
information and pressure values as an attachment.
Very clearly arranged and revamped as a PDF for
printing and submitting.
The software can be downloaded at
https://www.klauke.com/de/en/ipress-connectivity-software
Tool Information Display
When a battery is installed onto the tool, the following
information can be accessed.
1.
Install a charged battery onto the tool.
2.
Press the tool trigger to activate the display. Any
applicable error codes will be displayed. The 17
possible error codes are listed above. If an error
code is displayed, the tool’s red LED will also flash.
3.
The first screen will display whether tool is connected
via Bluetooth, the battery charge level, current
pressure & max pressure.
4.
Pressing the left button once will display the
firmware version, and tool serial number.
a.
Pressing the left button again displays the
current user.
b.
Pressing and holding both buttons lets you
select a current user.
c.
Use the right button to select the desired
user.
d.
Press the tool trigger to confirm selection
and return.
5.
Pressing the left button once again displays the
number of cycles and days until the next service
interval.
6.
Pressing the left button once again will display the
total operating hours, total Amp Hours (Ah) and total
number of cycles.
7.
Pressing the right button will allow you to go back to
the previous screen.