INSTALLATION  INSTRUCTIONS

Site Selection/Preparation

The spa must be installed on a structurally strong, solid and reasonably level surface. The
site should allow for drainage away from the equipment compartment in which the elec-
trical components are housed. Take into account the following when considering
prospective sites:

LOCAL CODES:

There may be certain restrictions and/or requirements that are particular to your locality.

DELIVERY PASSAGEWAY:

Doors, halls, stairs, etc. may pose obstructions to deliver the spa to its intended site.

MAINTENANCE:

Trees, lawn, placement surfaces, etc. can create extra work in keeping your spa and spa
area clean and safe.

PRIVACY & WIND SHIELDING

A sheltered environment can result in lower operating and maintenance costs.

ELECTRICAL REQUIREMENTS AND INSTALLATION:
Important:

Your spa is wired to meet the requirements of 

UL, ETL,

and the 

National

Electrical Code (NEC).

Any modifications required to meet state or local codes must be

performed by a qualified,

LICENSED

electrical contractor and approved by a local build-

ing/electrical inspection authority.

A ground terminal (pressure wire connector) is provided on the control box inside the
spa to permit connection of a minimum No. 8 AWG (8.4mm) solid copper bonding
conductor between this point and any metal equipment, metal enclosures or electrical
equipment, metal water pipe or conduit, within 5 feet (1.5m) of the unit as needed to
comply with local requirements.

In-Line Ground Fault Circuit Installation Diagrams

All wires feeding the spa are to be the same gauge. Ground wires are to be insulated.
When using a ground rod, the ground wire to the rod should be #6 bare copper wire.

All 220 Volt spas require the use of an isolated GFCI protected circuit. The installation of
a disconnect is required no more than ten (10) visual feet from the spa and not less than
five (5) feet from the spa. This requirement is to assure that the power cannot be
inadvertently turned back on when the power is disconnected from the spa for any
reason.

Wire your spa per the diagram most similar to your house panel.

220 Volts 3-wire systems:

Note: 220 volt spas use 3 wires: Ground, L1 and L2

— 5  —

Содержание Deluxe U -1 3

Страница 1: ...Manufactured by DM Industries Ltd TM Deluxe U 1 3 0 ...

Страница 2: ...ture 13 Setting Time and Filtration Hours 13 Auto Heat Operation 14 Jet Button 14 Light Button 14 Memory 14 Resetting Your Spa 15 Spa Maintenance Draining your spa 16 Winterizing your spa 16 Filter Maintenance 17 Marine Vinyl Cover 17 Water Quality and Maintenance General Guidelines for water 18 Diagnostic and Troubleshooting 19 Schematic 20 Maintenance Record 21 22 Warranty 23 Note All pumps must...

Страница 3: ...ur spa set up operation or mainte nance please contact DM Technical Support at the numbers below Owner s Record DATE PURCHASE __________________________________ SERIAL NUMBER __________________________________ To contact our Technical Service Department please call 1 800 316 7886 during normal business hours Monday through Friday 8 30am to 5pm EST The Serial Number is located within the equipment ...

Страница 4: ...the spa so proper drainage is provided for the compartment containing the electrical components 5 DANGER RISK OF ELECTRICAL SHOCK Placement of the spa shall be at least 5 feet 1 5 m from all metal surfaces A spa may be installed within 5 feet of a metal surface if each metal surface is perma nently connected by a minimum No 8 AWG 8 42mm2 solid copper conductor attached to the wire connector on the...

Страница 5: ...104 F DON T Operate spa without water Turn circuit breaker off before emp tying the spa and while it is empty DON T Store chemicals in the spa s equipment compartment C Before entering a spa the user should measure the water temperature with an accurate thermometer since the tolerances of water temper ature regulating devices vary D The use of alcohol drugs or medication before or during spa use m...

Страница 6: ... in pregnant women and 6 unconsciousness resulting in a danger of drowning WARNING The use of alcohol drugs or medication can greatly increase the risk of fatal hypothermia in hot tubs and spas Persons taking medications which induce drowsiness such as tranquilizers antihista mines or anticoagulants should not use the spa Pregnant women and persons with a medical history of heart disease circulato...

Страница 7: ...y a qualified LICENSED electrical contractor and approved by a local build ing electrical inspection authority A ground terminal pressure wire connector is provided on the control box inside the spa to permit connection of a minimum No 8 AWG 8 4mm solid copper bonding conductor between this point and any metal equipment metal enclosures or electrical equipment metal water pipe or conduit within 5 ...

Страница 8: ...g 2 TREE BRANCHES Clearance for spa passage 3 TIGHT CORNERS Make sure there is space to maneuver 4 STORAGE SHEDS DOG HOUSES WOOD PILES Remove out of the way 5 GATES CLEARANCE FOR PASSAGE OF SPA Does gate need to be removed from hinges 6 OVERHANGS AND GUTTERS Anything overhead as well as drain pipe locations must allow for spa passage 6 ...

Страница 9: ...E ROD SHOULD BE 6 BARE COPPER ALL SPAS REQUIRE THE USE OF AN ISOLATED GFCI PROTECTED CIRCUIT THE INSTALLATION OF A DISCONNECT IS REQUIRED NO MORE THAN TEN 10 VISU AL FEET FROM THE SPA AND NOT LESS THAN FIVE 5 FEET THIS REQUIREMENT IS TO ASSURE THAT WHEN POWER IS DISCONNECTED FROM THE SPA POWER CAN NOT BE INADVERTENTLY TURNED BACK ON ELECTRICAL REQUIREMENTS AND INST ALLA TION SEPARATE NEUTRAL SOLID...

Страница 10: ...COMMON NEUTRAL GROUND BAR IN MAIN SEPARATE NEUTRAL WEAK GROUND OR ROMEXWIRE USEDTO FEED GFCIWITH UNDERSIZED GROUNDWIRE 8 ...

Страница 11: ...GFCI IN PANELWITH SEPARATE NEUTRAL AND SOLID GROUNDTO PANEL GFCI IN PANELWITH COMMON NEUTRAL BAR AND OR ROMEXWITH UNDERSIZEDWIRE USEDTO FEED DIS CONNECT 9 ...

Страница 12: ...GFCI MOUNTED IN PANEL AND DISCONNECT MOUNTED INSIDETO COMMONWALLWITH METAL STUDS ORWITH METAL MOUNTING BOX GFCI IN PANELWITHWEAK GROUND OR ROMEXWITH UNDER SIZED GROUNDWIRE USEDTO FEED DISCONNECT 10 ...

Страница 13: ...ed The wire size for the distance of the wire run must conform to NEC and local electrical codes 5 To ensure proper connections use copper conductors only DO NOT USE ALUMINUM WIRE 6 The spas power terminal strip is located within the electrical control box 7 Feed supply conductors through power supply inlets provided on the spa and install into the control box Modifications to the electrical equip...

Страница 14: ...ighten a union fitting that may have come loose during transit Also check that the gate valves are pulled out to the open position and that the hose bib is closed Continue to fill to the water level line NOTE If your water is extremely hard it is preferable to fill the spa halfway with hard water and the rest with softened water NEVER FILL THE SPA ENTIRELY WITH SOFTENED WATER ADD START UP CHEMICAL...

Страница 15: ...G button will allow switching the display between time and water temperature The dis played temperature is the last reading taken when the pump was operational To verify water temperature when the pump is shut off press the jet button and allow the pump to run for two minutes The water tem perature sensor will analyze the water temperature during this time period and then display the current water...

Страница 16: ...apy pump mode E Jet Button Single Pump System 1 Press JET to activate the low speed pump 2 Press JET a second time to activate the high speed pump 3 Press JET button a third time to turn the pump off Note that the low speed pump will remain of if the water temperature is below the set temperature or if it is during the filtration hours Note that for safety the pump will automatically turn off afte...

Страница 17: ...m is not operating properly please follow the following resetting procedure 1 Turn the power to the off for 15 full minutes 2 Turn the power back on 3 Press PROG to show time 4 Press and hold the UP arrow for 5 seconds The control display will show 12 00 p m as soon as you release the UP arrow indicating a successful reset The set temperature and filtration hours will be reset to their factory pre...

Страница 18: ...y then pull The spa will empty by gravity Siphon or scoop out the balance of the water IMPORTANT Spa water with a high sanitizer level may harm plants and grasses If you are draining your spa for the winter be sure to fully drain water from the pipes by disconnecting the two unions at the gate valves Drain the water pump by removing the pump plug Then reinstall the valves and pump plug C Remove th...

Страница 19: ... filter This way one can be soaking and cleaning while you continue to enjoy the use of your spa 4 MARINE VINYL COVER Your cover is manufactured from a durable marine grade U V resistant material Even so monthly cleaning and periodic conditioning is recommended to maintain its beauty To clean and condition the vinyl cover A Lightly spray the cover with a garden hose to rinse it and remove the debr...

Страница 20: ...f tablets the amount of time the floater is open and the length of the filtration cycles you can control the amount of bromine in your spa A bromine residual of 2 to 3 PPM is generally considered desirable A two part bromine system or a granular chlorine dichlor system is also acceptable Sanitizers pH CONTROL pH is a measure of acidity and alkalinity of the spa water The recommended pH for spa wat...

Страница 21: ...ctrician if it will not start MESSAGE FLO Lack of water flow through heater Remove filter and check for debris in the filter and filter adapter If FLO remains check for closed gate valve or see priming the pumps HILI Message appears if the heater Remove spa cover and sensor detects 118F at heater let the spa water temperature cool Reset spa ICE Water in plumbing below 50F No action required Pump w...

Страница 22: ...Maintenance Record Keep track of your water maintenance 21 ...

Страница 23: ... 20 Schematic U U130 Terminal Block Transformer Pressure Switch Heater Circuit Board ...

Страница 24: ...cement spa will be the responsibility of the spa owner EXCLUSIONS This warranty is void if DM Industries Ltd or its representative deter mines that the spa has been subjected to any alterations or repairs by anyone other than an authorized representative of DM Industries Ltd Eco Spas are NOT APPROVED for commercial applications DM Industries Ltd will not be responsible for the cost of replacement ...

Страница 25: ... 2005 DM Industries Ltd 2320 NW 147th Street Miami Florida 33054 PH 305 685 5739 ECODX 05 0517 ...

Отзывы: