![DLS MRA22 Скачать руководство пользователя страница 7](http://html.mh-extra.com/html/dls/mra22/mra22_manual_2513034007.webp)
Two fullrange speakers to MRA22
With the HPF-filter in OFF position the amplifier
allows the speakers to play fullrange. If you for
some reason want to limit the low bass
reproduction switch on the HPF-filter.
The typical setting is then 60 – 80 Hz.
The LPF-filter should be OFF.
One subwoofer connected in bridge mode to
MRA22
The HPF filter is here used as subsonic filter to take
away the very deepest frequencies. The typical set-
ting is around 25 – 40 Hz.
The LPF will allow low frequencies only and blocks
higher frequencies. A typical setting is 70 – 90 Hz.
LPF
Off On
80Hz 200Hz
50Hz 500Hz
Filter settings
NOTE!
4 ohm minimum load when using bridge mode
connection. Lower impedances may damage the
amplifier. In bridge mode the amplifier sees a 4
ohm load as 2 ohm.
Filter settings
MRA22
Speaker wiring MRA 22
HPF
Off On
50Hz 220Hz
15Hz 500Hz
HPF
Off On
50Hz 220Hz
15Hz 500Hz
LPF
Off On
80Hz 200Hz
50Hz 500Hz