Installation
60
Manual
DLoG MPC 6
Figure 7.2: Position of the ground bolt
•
The other end of the yellow-green supply voltage cable should be connected to the
vehicle’s chassis .
•
Make sure that the DLoG MPC 6’s connecting cable is attached as close to the
battery as possible. Connecting the DLoG MPC 6 to large electrical loads, such as
converters for the forklift motor may result in random restarts, malfunctions and/or
irreparable damage to the device.
•
If you want to connect devices fed by other power sources to the DLoG MPC 6,
such as certain PS/2-Wedges, printers and so on, be sure to power up the
peripheral devices at the
same time
or
after
the DLoG MPC 6. Otherwise, you
may encounter start-up problems, malfunctions or even irreparable damage to the
device.
Position of the ground bolt