Important notice:
Together with the First Feeder device a 2 metre long water hose is
delivered, with a connector at one end and a pressure regulating
valve at the other.
It is crucial for correct operation of the device, that the end with
the connector is mounted on the First Feeder and water supply is
connected to the pressure regulating valve.
The hose acts as a pressure accumulator and equalizes water
pressure. Therefore, only the originally supplied hose may be used
between the First Feeder and the pressure regulating valve, as it
has the correct damping ability.
Connect a water supply pipe to the pressure regulating valve on the
First Feeder. In order to achieve optimal operation of the device,
the water pressure should be at least 2 bar and
the supply pipe should be at least 0.5 inch in diameter. Water
supply connector to the First Feeder, i.e. to the pressure regulating
valve, is 0.5 inch in diameter (internal pipe thread). Install the
supplied filter between the water supply and the pressure
regulating valve.