12
2.4.2 Working mode
SOLUNA S12 EU have the below working modes for your home made energy
storage system.
●
Self Use
In the “Self Use” mode the priority of the PV generated power will be :local
load>battery >public grid. It means the PV generated power will be used in local
load then the battery charging and the redundancy power will be delivered to the
public grid.
●
Peak shaving Use
In the “Force Time Use” mode ,user can set the charging and discharging time
according to his wishes and also can chose if charge from grid if allowed.
●
EPS mode
The SOLUNA S12 EU version integrated with EPS function. The inverter will
automatically switch to EPS output when the grid if off. User need to set the battery
remaining value for the EPS. When use the EPS function, need to fit the load
power rating with the EPS power rating
2.5 Technical data
2.5.1 Technical data of System
System capacity
Unit
Nominal Storage capacity
11.52
kWh
Usable Storage Capacity
10.35
kWh
PV
Max. recommended DC power
6600
W
Max. DC voltage
500
VDC
Nominal DC operating voltage
360
VDC
MPPT voltage range
120-450
VDC
Max. input current
13*2
A
Max. short current
15.6*2
A
Number of MPPT trackers
2
Strings per MPPT tracker
1
AC Output
AC nominal power
4600
W
Max. AC current
20
A
Max. AC short current
30
A
Max. AC protection current
30
A
Nominal AC voltage/Range
230 ;180~270
VAC
Grid Frequency/Range
50(45-54) / 60(55-65)
Hz
Power factor (rated power)
≥0.99
Содержание SOLUNA S12 EU
Страница 1: ...1 User Manual SOLUNA Home Storage System S12 EU DLG Energy Shanghai Co Ltd July 2019 Revision A 0 ...
Страница 15: ...15 2 6 Appearance Figure 2 3 Appearance Number Name Remark Soluna bread LCD panel ...
Страница 16: ...16 Figure 2 4 Appearance Number Name Remark System outlet System outlet Emergency Stop System inlet Label ...
Страница 17: ...17 Figure 2 5 Appearance Number Name Remark Door lock of system Key ...
Страница 18: ...18 3 Installation 3 1 Installation tools ...