ARG1 : get, set
ARG2 : get - sysinfo. MPU module Information
status. MPU module Status
config. MPU module Configuration
inpower. Input Power Value of MPU Module
set - time.
descr. MPU Description
als. Machine All ALS Control
buzz. MPU Buzzer Setting
ARG3 : time - Set New Time. [YYYYMMDDhhmmss]
descr - Enter User define string.[Len:0 ~ 20]
als - ON, OFF
buzz - ON, OFF
--------------------------------------------------------
MPU SET DESCR [Len
: 0
~20]: Input MPU Description
ex) MPU SET DESCR Shelf-OFA for Node 1
MPU SET TIME [YYYYMMDDhhmmss]
: Input time information for MPU. Use 14 digits to
input the time information, such as [YYYYMMDDhhmmss].
ex) MPU SET TIME 20061207091830
MPU GET SYSINFO : View MPU Model Name, Description, Serial Number, Firmware
Version, Hardware Version.
ex)
ADMIN:> mpu get sysinfo
--------------------------------------------------------
Model Name :
Description :
Serial Number :
Hardware Version : 1.00
Firmware Version : 1.00
--------------------------------------------------------
MPU GET_STATUS : View MPU time information.
ex)
ADMIN:> mpu get status
--------------------------------------------------
Current Time : 2012/04/06 19:56:28
Provision (Bit) : 0x1
Card ACT (Bit) : 0x1
Card Alarm (Bit) : 0x0
--------------------------------------------------
5.1.1.10
SHELF
Basic information of shelf system
ex)
ADMIN:> shelf
--------------------------------------------------------
Usage : shelf [ARG1] [ARG2] [ARG3] [ARG4]
ARG1 : get, set
ARG2 : get - info - SHELF system information
psinfo - Power Supply Output Power
faninfo - FAN status
alarm - Now, all alarm value of shelf system
systh - Alarm threshold value of shelf system
log - System log information
set - psen - Power Supply Alarm Enable/Disable
log - Log clear.
AGR3 : psen - index (1 ~ 2)