Network Managed Optical Amplifier
User’s Manual Rev 1.3
OFA-CCS/CCD Series
June 2014
18
The Temperature is the EDFA module temperature. The unit is centigrade [
℃
].
Using the Alarm menu you are able to check the EDFA Alarms.
To move another alarm state, push Up/Down switch.
…
Table 8. Alarm Descriptions
Name
Variable
Descriptions
CaseTemp
IPM
OPM
POWER 1
POWER 2
FAN 1
FAN 2
LD1 BIAS
LD1 THER
Case Temperature
Input Power
Output Power
Power Supply 1
Power Supply 2
Fan1
Fan2
Current
Thermistor
Shows the temperature state of the EDFA
module. (OK: Normal, FAIL: Abnormal)
Shows the input optical signal power of the
EDFA. (OK: Normal, FAIL: Abnormal)
Shows the output optical power of the EDFA.
(OK: Normal, FAIL: Abnormal)
Shows the Power Supply state of the EDFA
module. (OK: Normal, FAIL: Abnormal)
Shows the Power Supply state of the EDFA
module. (OK: Normal, FAIL: Abnormal)
Shows the FAN state of the EDFA module
(OK: Normal, FAIL: Abnormal)
Shows the FAN state of the EDFA module
(OK: Normal, FAIL: Abnormal)
Shows the state of the Pump Laser Diode Bias
current. (OK: Normal, FAIL: Abnormal)
Shows the temperature state of the Pump Laser
Diode. (OK: Normal, FAIL: Abnormal)
EDFA Model Name is the EDFA model name of built in the Shelf.
LD Thermistor
LD1 : XX
℃
LD Thermistor
LDx : XX
℃
Temperature
> Alarm Status
CaseTemp : OK
IPM : OK
IPM : OK
OPM : OK
LD1 Ther : OK
CaseTemp : OK