3. Caution Point in Operation
3.1 Condition of using
· Ambient temperature on -10�~+40
℃
� (14�~104
℉
), humidity max. 85%
· Avoid the place has a lot amount of straight sunlight, water and oil.
· Avoid the place has amount of dusty, inflammable gas or corrosive
gas.
3.2 Overhung load and thrust load
· Permissible overhung load and permissible thrust load
(Figure 3-1)
Model
Ratio
Max. Permissible
Torque
Overhung
Load
Thrust
Load
N.m
Kgfcm
N
Kg
N
Kg
6GBD
□
MH
3~18
3
30
50
5
30
3
20~250
120
12
7GBD
□
BMH
3~18
5
50
80
8
40
4
25~180
150
15
8GBK
□
BMH
3~18
8
80
100
10
50
5
25~360
200
20
9GBK
□
BMH
2~18
10
100
250
25
100
10
25~180
300
30
9PBK
□
BH
9PFK
□
BH
2~9
20
200
400
40
150
15
12.5~20
450
45
25~180
500
50
9HBK
□
BH
9HFK
□
BH
3~180
30
300
400
40
150
15
8WD
□
BL(R)
10~18
6
60
80
8
100
10
25~60
150
15
9WD
□
BL(R)
10~18
8
80
200
20
200
20
25~60
250
25
9WHD
□
7.5~80
40
400
500*
50*
250
25
11
Содержание GEARHEAD
Страница 2: ......
Страница 4: ...1 1...
Страница 7: ...4 3 Overhung 10mm Overhung 10mm Helical Gear Worm Gear Overhung Thrust 3 1 Overhung 3 3...
Страница 8: ...4 4 1 1 2 3 4 2 4 5mm Box Type Gearhead Flange Type Gearhead 5...
Страница 10: ...5 A S 1 2 3 4 1 2 1 Thermal Protector TP 2 Pulley 3 4 Overhung 3 5 3 3 7...
Страница 12: ...1 Product Coding System 9...