20030929 

 

Document no. 477-2010A page 3 of 3 

13. DC-warning.

 Any DC content in the audio signal is deliberately filtered out and will not affect the reading. The 

DC LED will however indicate if abnormal DC levels are present in the audio signal.

 

14. Overload 

LED. 

Overload indication, left channel.

 

15. Overload 

LED. 

Overload indication, right channel.

 

 
 

NOTE: On some versions the buttons 1-4 have been omitted for simplicity reasons.  
 
 
 

Instrument set-up. 

Numerous parameters  (like ref. level etc.)  may be set by means of the four buttons on the front. 
Normally the standard parameters set by the factory will be satisfactory and therefore no adjustments are needed. 
Any adjustment should be done by skilled personnel following the instructions below. 
In the following the buttons are referred to by numbers (1,2,3,4) where “1” is the leftmost button (or upper on horizontal 
scales). Press button 1 is written: [1]. Two buttons may be pressed simultaneously i.e. [1+3]. 
 

Adjustment of reference level:

 

 

1.  Press [1+3] and hold for more than 1.6 s. The display will be lit in both channels with markings pr. 1 dB. 
2.  Press [3] to decrease reference level in 1 dB steps. Scale max. equals digital FS. 
3.  Press [4] to increase reference level in 1 dB steps. Scale max. equals digital FS. 
4.  Press [1] to save settings and resume to normal operation. (Or press [2] to jump to next adjustment point 2) 

 

Activating / deactivating display ballistics: 

 

1.  Press [1+3] and hold for more than 1.6 s. The display will be lit in both channels with markings pr. 1 dB. 
2.  Press [2]. The display will be lit in the left channel with markings pr. 1dB. 
3.  Press [2]. The display will be lit in the right channel with markings pr. 1sample. 
4.  Press [2]. The left overload LED will be lit. 
5.  Press [3] or [4] to toggle display ballistics on/off. Ballistics is on when the right overload LED is lit. 
6.  Press [1] to save settings and resume to normal operation. 

 

Compensation for “ghost” spot. (Only required if display is replaced. 

 

1.  Press [1+3] and hold for more than 1.6 s. The display will be lit in both channels with markings pr. 1 dB. 
2.  Press [1] and hold for more than 6 s. All LED’s are lit in sequence for inspection. 
3.  Press [2] The display will be lit in both channels with a falling spot in the right channel. 
4.  Press [3] if a bright “ghost” of the spot appears in the left channel. 
5.  Press [4] if a dark “ghost” of the spot appears in the left channel. 
6.  Press [1] to save settings and resume to normal operation. 

 

Содержание 477-200A

Страница 1: ...20030929 Document no 477 2010A page 1 of 1 Digital Peak Programme Meter 477 200A Users Manual ...

Страница 2: ...The spot responds to the fastest peaks on the signal 0 integration time The calibration of the spot reading is such that the mark 0 or the start of overload range equals digital full scale level This means that the distance between the spot indication and the mark 0 on the shown scale represents the true head room before digital clipping This means that even with an analogue type scale and 10ms in...

Страница 3: ... reference level in 1 dB steps Scale max equals digital FS 3 Press 4 to increase reference level in 1 dB steps Scale max equals digital FS 4 Press 1 to save settings and resume to normal operation Or press 2 to jump to next adjustment point 2 Activating deactivating display ballistics 1 Press 1 3 and hold for more than 1 6 s The display will be lit in both channels with markings pr 1 dB 2 Press 2 ...

Страница 4: ...he two connectors should be in the 110 Ώ position Power connector Power is supplied through the coaxial low voltage socket A mating connector should have an outher diameter of 5 5mm and a hole diameter of 2 1mm Either a 24V dc or a 18V ac sypply should be used Remote Control Remote control and additional power connection is accessible through the 9pole male D sub connector on the rear side Pin con...

Страница 5: ...ference level is set as described under Operating Parameter Settings If however a resistor is connected to 0V the preset reference level will be overruled The resistor value required to obtain a given reference level can be found in table 1 It may be necessary to use resistors in parallel or series to obtain a specific value to within 2 Table 1 Reference Resistor Reference Resistor level value ohm...

Страница 6: ...e 0 to 31 dB below max digital code Overload indication the bar intensity is increased within overload range Low frequency cut off DC blocking Cut off frequency 0 3 Hz Secondary reading spot Integration time zero Return time 1 7 s 0 3 s 0 to 20 dB IEC 268 10 1991 03 Scale max Scale max equals the lower limit of intensified bar range Reference level Scale max corresponds to max digital code level P...

Отзывы: