background image

V-1 SPARK MACHINE Art.No.: 118428 
 

5 / 16

 

A usage of the device which differs from usages which are described in this 
manual can cause damages of the device.  In this case the warranty expires. 
Additional you should notice that every different usage is related with 

dangers and can cause e.g. an electrical short, fire, electric shock or crash.  

2.1.

 

 Overhead installation 

 

 

Danger of life! 
You have to observe the regulations of BGV C1 (formerly VBG 
70) and EN60598-2-17 Installations are to carry out by skilled 

personnel only.

 

The suspension devices have to be build and measured so they can 

withstand for an hour the tenfold of the payload without suffering a 
permanent detrimental deformation. 
Basically installation has to be made by using a second separate suspension. 
This can be e.g. a suitable net. The second suspension must be designed and 
attached so no part of the installation can fall down in case of failure. 
During construction, reconstruction and deconstruction unnecessary stay in 
the range of moving areas, on lightning bridges, under elevated work stations 

or any other danger zones is forbidden. 
The operator is obliged to following safety-related and mechanical facilities:  

 

Before the first start-up or after critical changes before restarting it has 
to be checked by an expert. 

 

Review in the frame of the inspection test at least all four years by an 
expert.  . 

 

Review by a qualified person at least once a year. 

How to carry out the overhead installation: 

Ideally the device should be installed outside lounge areas of people.  

IMPORTANT!

 Overhead installation requires a high level of experience. This 

includes knowledge of calculating the payload, used installation material 
and safety inspections of the used material and the projector whereas the 
required experience is not limited to this. Do not try to carry out installation 
yourself under any circumstances if you are not qualified. Contact a 
professional installer. An inappropriate installation can lead to injuries and/or 
damaged properties. 
It is not allowed to install the device in the grip area of people. 
If the device may hang from the ceiling or from high beams, the use of truss 
systems is mandatory. The device may not be installed so it can swing freely in 
the room. 
Please note: Crashing down items can cause serious injuries! Do not install the 
projector, if you doubt the safety of a possible installation form! 

Содержание V-1

Страница 1: ...V 1 USER S MANUAL ...

Страница 2: ...3 DMX connection with terminator 7 3 Introduction 8 3 1 Product description 8 4 Before using 9 5 Control buttons 9 6 User Interface 10 6 1 Status interface 10 6 2 Menu 11 6 3 DMX Interface 11 7 Error 12 8 Operation 13 8 1 Manual Operation 13 8 2 Operation via DMX 13 9 Settings 14 9 1 DMX address 14 9 2 Fan speed setting 14 9 3 Manual operation 14 10 RFID card 14 10 1 How to use the card 14 10 2 Ho...

Страница 3: ...tions always place the device on a firm ground Do not use chemicals for cleaning Use a clean and dry cleaning rag to remove dust Metal parts can be cleaned with a damped cleaning rag Before cleaning always unplug the device from the power supply If the device is not working properly If problems occur unplug the device from the power supply The user should not try to service the device independentl...

Страница 4: ...e Unplug the power supply during thunderstorms Surrounding objects or surfaces should not be in contact with the device Make sure that during the installation and removal of the device the area below the place of installation is basically cordoned off This also applies to implementation of service Make familiar yourself with the functions of the device before start up People without the experience...

Страница 5: ...s forbidden The operator is obliged to following safety related and mechanical facilities Before the first start up or after critical changes before restarting it has to be checked by an expert Review in the frame of the inspection test at least all four years by an expert Review by a qualified person at least once a year How to carry out the overhead installation Ideally the device should be inst...

Страница 6: ...e hole of the mounting bracket Direct the rope over the truss or an appropriate fastening point Hang up the end in the fastening element and tie up the locking nut A safety rope once exposed to failing load or damaged may not be used furthermore The maximum drop exceed must not exceed 20cm A safety rope once exposed to failing load or damaged may not be used furthermore Adjust the desired inclinat...

Страница 7: ...e or the equipment is operated in an electrically noisy environment like a disco for installations we recommend using a DMX terminator This prevents corruption of the digital control signal by electrical noise The DMX terminator is simply an XLR connector with a 120 Ω resistor between pins 2 and 3 which is then plugged into the XLR output socket of the last device in the series Please look to the ...

Страница 8: ...commissioning the unit Please follow the instructions in this manual This is the only way to ensure safe operation proper use and long service life 3 1 Product description 1 Nozzle 2 Feed port 3 Storage bin cover 4 Air Outlet 5 Control panel 6 XLR 3pol INPUT OUTPUT 7 XLR 5pol INPUT OUTPUT 8 Fuse 9 Power OUTPUT 10 Power INPUT 11 On Off switch 12 Air Inlet 13 Handle ...

Страница 9: ... up This process needs 4 min meanwhile the display shows Heating 4 The heating process is finished The display shows Ready To Work 5 Now you have to fill in the granules More information for this you can read on the packing of the granules You are only allowed to use the granules of DJ Power 5 Control buttons Button Function MENU Navigation through the menu Increase a value or make a setting Decre...

Страница 10: ...ating Current temperature is 200 C Device Fault E0 The unit stops to over temperature Device Fault E1 The unit failed to heat Device Fault E2 Feeding motor is protected Device Fault E3 Temperature sensor failed Device Fault E4 Temperature sensor tripped off NO Time E5 The granules are run out soon Device Fault E6 Temperature inside the unit is too high Device Fault E7 Step motor is not able to res...

Страница 11: ...lus Time XX Min XX Sec Check out the remaining time of using 6 3 DMX Interface Display Meaning DMX Address Set Ready 1 The unit is ready to work Current DMX address is 1 DMX Address Set 1 Heating The unit is heating Current DMX address is 1 DMX Address Set Device Fault 1 The unit failed Current DMX address is 1 DMX Address Set No Time 1 Materials are to run out soon Current DMX address is 1 DMX Ad...

Страница 12: ...vice did not reach the working temperature after 10 min E2 Over current protection of the motor Error of the motor E3 Thermocouple failed Short circuit or wrong connection E4 Thermocouple tripped off Open circuit or no connection E5 No enough time Granules run out soon E6 Over temperature inside the unit The temperature inside the unit is higher than 60 C E7 Step motor problem The step motor is no...

Страница 13: ...s Ready To Work press Menu until the display shows Menu Fountain With the buttons and buttons you can choose On Off 8 2 Operation via DMX Channel Value from Value to Function 1 0 9 No Function 10 35 Height 1 36 60 Height 2 61 85 Height 3 86 110 Height 4 111 135 Height 5 135 160 Height 6 161 185 Height 7 186 210 Height 8 211 235 Height 9 236 255 Height 10 2 0 9 Normal operation 10 60 Clear material...

Страница 14: ... to Work after the unit finishes heating Press MENU button till page Manual Fountain Turn on OFF the Manual fountain through and When the temp is lower than 520 or the unit failed this function will shut off automatically 10 RFID card 10 1 How to use the card Tap the IC Card in the card reader area to activate the unit Each card enables the unit to work 25 minutes In the meantime the IC card will ...

Страница 15: ... 16 11 Technical dato Voltage AC 220 V 50 Hz Power consumption max 700 W Heating time 3 Minutes Consumption 14 g min Height of the fountains 1 5 Meter Stand By Temperature 580 C Max Loudness 94 dB Number of DMX channels 2 Strom in P Con ...

Страница 16: ...V 1 SPARK MACHINE Art No 118428 16 16 Importer B K Braun GmbH Im Stöckmädle 27 D 76307 Karlsbad www bkbraun com info bkbraun com ...