DJI Mavic 3E/3T
User Manual
40
©
2022 DJI All Rights Reserved.
• DO NOT charge an Intelligent Flight Battery immediately after flight as it may be too
hot. Wait for the battery to cool down to the operating temperature before charging
again.
• The charger stops charging the battery if the battery cell temperature is not within the
operating range of 5° to 40° C (41° to 104° F). The ideal charging temperature is from
22° to 28° C (71.6° to 82.4° F).
• Fully charge the battery at least once every three months to maintain battery health.
• DJI does not take any responsibility for damage caused by third-party chargers.
For safety purposes, keep the batteries at a low power level in transit. This can be done by
flying the aircraft outdoors until there is less than 30% charge left.
The table below shows the battery level during charging.
LED1
LED2
LED3
LED4
Battery Level
1%-50%
51%-75%
76%-99%
100%
Battery Protection Mechanisms
The battery level LEDs can display battery protection notifications triggered by abnormal
charging conditions.
Battery Protection Mechanisms
LED1 LED2 LED3 LED4 Blinking Pattern
Status
LED2 blinks twice per second
Overcurrent detected
LED2 blinks three times per second Short circuit detected
LED3 blinks twice per second
Overcharge detected
LED3 blinks three times per second Over-voltage charger
detected
LED4 blinks twice per second
Charging temperature is
too low
LED4 blinks three times per second Charging temperature is
too high