PUMP
15
Instruction & Operation Manual
800.789.1718
Installation
•
An isolation valve should be installed at both the suction and
discharge sides of the pump. This will allow you to remove
the pump for preventative maintenance or repair without the
need to drain your system.
(see the diagram to the right)
•
If pump is not in a flooded suction condition, install either a
foot valve or system check valve to ensure pump casing is
flooded for priming.
•
In order to provide pump flow rate control, a control valve
should be installed in the discharge piping to prevent motor
overload.
Piping: Valve Location
MINIMUM LENGTH
= 10 X DIAMETER
DIAMETER
CHECK
VALVE
CONTROL
VALVE
MINIMUM LENGTH = 8 X DIAMETER
DIAMETER
ISOLATION
VALVE
PSI
All power must be off and locked out during the installation process.
Only registered electricians should do the electrical installation.
Electrical
•
Follow motor manufacturer’s installation procedures.
•
Verify motor nameplate data is compatible with existing
electrical supply.
•
Verify pump rotation. An arrow sticker is supplied with every
pump to show correct pump rotation. If the arrow stickers are
missing, contact Dixon Sanitary for a replacement.
•
Correct rotation is counter clockwise when facing pump inlet
connection.