Dixon B5107 Скачать руководство пользователя страница 30

30

 

dixonvalve.com • 800.789.

1718

 

Dixon B

5107

 Series Butterfly Valves 

| IOM

 

Limited Warranty 

 

DIXON VALVE AND COUPLING COMPANY (herein called "Dixon") warrants the products described herein and manufactured by 

Dixon to be free from defects in material and workmanship for a period of one (1) year from date of shipment by Dixon under normal 

use and service. Its sole obligation under this warranty being limited to repairing or replacing, as hereinafter provided, at its option 

any product found to Dixon's satisfaction to be defective upon examination by it, provided that such product shall be returned for 

inspection to Dixon's factory within three (3) months after discovery of the defect. The repair or replacement of defective products 

will be made without charge for parts or labor. This warranty shall not apply to: (a) parts or products not manufactured by Dixon,

 

the warranty of such items being limited to the actual warranty extended to Dixon by its supplier; (b) any product that has been 

subject to abuse, negligence, accident, or misapplication; (c) any product altered or repaired by others than Dixon; and (d) to normal 

maintenance services and the replacement of service items (such as washers, gaskets and lubricants) made in connection with 

such services. To the extent permitted by law, this limited warranty shall extend only to the buyer and any other person reasonably 

expected to use or consume the goods who is injured in person by any breach of the warranty. No action may be brought against

 

Dixon for an alleged breach of warranty unless such action is instituted within one (1) year from the date the cause of action accrues. 

This limited warranty shall be construed and enforced to the fullest extent allowable by applicable law.

 

 

 

Other than the obligation of Dixon set forth herein, Dixon disclaims all warranties, express or implied, including but not limited to any 

implied warranties of merchantability or fitness for a particular purpose, and any other obligation or liability. The foregoing constitutes 

Dixon's sole obligation with respect to damages, whether direct, incidental or consequential, resulting from the use or performance of 

the product.

 

 

Some products and sizes may be discontinued when stock is depleted or may require a minimum quantity for ordering 

 

 

Содержание B5107

Страница 1: ...Instruction Operation Manual for B5107 Butterfly Valve Read and understand this manual prior to installing operating or servicing this equipment Rev D...

Страница 2: ...ns 6 8 Installation and Start Up Unpacking 9 Tools Needed 9 Welding 9 Function Testing 10 Orientation 10 General Maintenance Maintenance Intervals 14 Lubrication 14 Inspection 15 Cleaning 13 15 Assemb...

Страница 3: ...ixon product in any application that exceeds the product rating General Guidelines The owner must comply exclusively with these operating instructions and the authorized use of this piece of equipment...

Страница 4: ...or All safety and warning notices attached to the equipment are legible and none are removed The operating instructions are always kept close to the product operation site in a legible and complete st...

Страница 5: ...scoloration stress cracks Permanent damage often occurs from excessive chemical concentrations temperatures or exposure times 6 For manual cleaning use only soft non metallic brushes sponges or pads B...

Страница 6: ...a max operating temperature 200 F 93 C minimum operating temperature 15 F 9 C Surface Finish Technical Data product contact components Ra 32 optional finishes 15Ra 20Ra 25Ra Pneumatic Connections Tech...

Страница 7: ...48 175 2 5in 133 98 220 3 0in 133 146 310 4 0in 266 341 450 6 0in 775 830 NA 8 0in 1106 1106 NA Equipment Serial Tags All Dixon butterfly valves assembled at the factory in Pewaukee WI with pneumatic...

Страница 8: ...410 3 2 2 4 1 2 0 3 450 3 8 2 9 1 5 0 3 490 4 5 3 4 1 7 0 4 0 2 530 4 0 2 0 0 4 0 2 570 4 7 2 3 0 5 0 2 610 5 3 2 7 0 6 0 3 650 6 1 3 1 0 7 0 3 690 6 8 3 4 0 7 0 3 730 3 9 0 8 0 4 770 4 3 0 9 0 4 810...

Страница 9: ...the following components Item Description 1 Butterfly valve 2a Pull Handle 2b Infinite Handle 2c Trigger Handle 3 Canister Actuator Tools Needed The following tools are required for maintenance of th...

Страница 10: ...nual has beencomplied with For manual handle valves open and close the handle several times to ensure that the valve operates without any difficulty See valve operation section in the installation and...

Страница 11: ...ty Max dew point temperature 3 C 37 4 F Installations at lower temperature or varying altitudes my require adjustments accordingly Air Consumption liters free air 0 24 x Supply Pressure bar For normal...

Страница 12: ...p 1 and ensure that the handle plunger locks into one of the four holes machined on the handle hub Step 1 Rotate handle knob counterclockwise to unlock the handle Step 2 Rotate the handle to the desir...

Страница 13: ...hat will attack stainless steel or the elastomers that were supplied with the valve If you are unsure what elastomer is used in the valve reference the part number key in this manual to make the deter...

Страница 14: ...ner can determine the appropriate service intervals as the length between service intervals is dependent on the following parameters duration of use per day number of cycles type of product product te...

Страница 15: ...y components that show signs of severe wear or damage should be replaced during the scheduled maintenance time for the equipment Please refer to the assembly and disassembly section of this manual for...

Страница 16: ...ee Figure B Pinch the seat between your thumb and index finger Slide the long end of the disc stem through the hole in the seat Stretch the remaining end of the seat over the short end of the disc ste...

Страница 17: ...onto the valve stem 4 Slide the actuator bracket item 7 over the valve body item 3 and align the bolt holes of the bracket with the holes in the valve body 5 Insert the hex head bolts item 1 through t...

Страница 18: ...Ring item 6 and fit the O Ring into the O Ring groove of the adapter item 3 8 Insert the hex head bolts item 4 through the holes in the adapter item 3 and thread into the top of the actuator item 8 T...

Страница 19: ...queeze the seat between your thumb and index finger as shown in Figure A of the assembly procedure and pry the seat over and off the short end of the valve stem 7 Pull the disc out completely from the...

Страница 20: ...B5107 RKV250 B5107 FKM Repair Kit For 2 5in Valves B5107 RKV300 B5107 FKM Repair Kit For 3in Valves B5107 RKV400 B5107 FKM Repair Kit For 4in Valves B5107 RKS100 B5107 Silicone Repair Kit For 0 5in 1i...

Страница 21: ...B5107 HSG800 316L 2 Yes 3 Valve Seat See Repair Kits See Repair Kits See Repair Kits See Repair Kits See Repair Kits 1 Yes 4 Disc B5107 DSC25 B5107 DSC30 B5107 DSC40 B5107 DSC60 B5107 DSC800 316L 1 Ye...

Страница 22: ...04 1 Yes 2 5in 3in 4in 6in 8in 1 Body Bolt M8x1 25x35 18 8 2 No 2 Body Nut 18 8 2 No 3 Valve B5107_250__ B5107_300__ B5107_400__ 1 Yes 4 Indicator Polyethylene 1 Yes 5 Coupler CF8 1 Yes 6 Actuator Bol...

Страница 23: ...BT AS 24S M12 1 Yes Burkert 8691 Top 24VDC AS I Double Acting G1 8 Air Ports Contact Free Switches Nema 4X M12 4pin BT AS 24D M12 1 Yes Burkert 8691 Top No Solenoids Contact Free Switches Nema 4X M12...

Страница 24: ...O Output 6mm Sensing Distance Shielded IP67 4 Pin M12 Male Quick Disconnect DW AS 503 M12 1 Yes M12 Inductve Prox Sensor 50mm Body NPN N O Output 6mm Distance Shielded IP67 Cable Hard Wired To Sensor...

Страница 25: ...Bearing VC1 8 2 304 See VC1 RK1 5 Thrust Bearing VC1 10 2 304 See VC1 RK1 6 Drive O Ring VC1 11 1 EPDM See VC1 RK1 7 Actuator Drive VC1 2 1 304 Yes 8 Drive Needle Bearing VC1 9 2 304 See VC1 RK1 9 Th...

Страница 26: ...will have Qty 2 air fittings Double acting actuators do not have an inner or outer spring Dimensions Valve with Canister Actuator Valve Size Dimension Units in A B C D E F G H 1 2 3 5 3 1 2 7 8 7 9 6...

Страница 27: ...r current valve is constructed of refer to the complete part number that is laser marked on the valve If you require an option that is not listed in this key please feel free to contact Dixon Sanitary...

Страница 28: ...Pneumatic Positioner 3 15psi input 2 SPDT Mech Switches for Feedback 23 Rotary Pneumatic Positioner 3 15psi input 4 20mA for Feedback 24 Rotary Electropneumatic Positioner 4 20mA input no Feedback 25...

Страница 29: ...ions Actuator is clogged with debris Check the actuator clean Actuator component is worn out Replace worn components WATER HAMMER The valve is closing too fast Install a flow regulator to adjust the c...

Страница 30: ...ication c any product altered or repaired by others than Dixon and d to normal maintenance services and the replacement of service items such as washers gaskets and lubricants made in connection with...

Страница 31: ...nge of products for numerous industries including petroleum exploration refining transportation chemical processing food beverage steel fire protection construction mining and manufacturing Dixon s st...

Отзывы: