REFRIGERATION TROUBLESHOOTING
Page 77 of 23
PRODUCT HOT
Possible Cause:
Compressor starts, but will not keep running.
WHAT TO CHECK
SOLUTION
1. Is the temperature control knob set on its highest setting?
YES
2. Domestically, is the voltage supply b/- 10% of rating on the
serial plate?
YES
3. Is the condenser clear of obstructions?
YES
4. Is the condenser fan blade turning?
YES
5. Is the condenser fan motor operational?
YES
6. Is the temperature control operational?
YES
7. Is the tube from the compressor to condenser free of kinks?
YES
8. Is the capillary tube free of kinks?
YES
9. Is the thermal overload operational?
YES
10. Is the start relay operational?
YES
11. Consult the Dixie -Narco Factory Service at 1-800-688-9090 or your
Dixie-Narco Representative.
NOTE: Have the vender Model & Serial number available.
1. NO,
adjust the knob to a higher
setting.
2. NO,
consult the power company.
3. NO,
clear or clean.
4. NO,
free the obstruction or check
the blade if needed.
5. NO,
check.
6. NO,
check.
7. NO,
repair or check.
8. NO,
check.
9. NO,
check.
10. NO,
check.
11. NO,
check.