background image

dIXEL

 

Installing and Operating Instructions

 

1592018110 

 

1592018110 XR460C GB r1.0 04.07.2005 

 

XR460C

 

5/5 

Frontal protection: IP65 with frontal gasket RG-C (optional). 
Connections: Screw terminal block 

 2,5 mm

2

 heat-resistant wiring. 

Power supply: 12Vac/dc (opt.24Vac/dc), ±10% 
Power absorption: 5VA max. 
Inputs: 3 NTC or PTC probes 
Relay outputs 
 compressor1: 

SPST relay 8(3) A, 250Vac or  

 compressor 

2: relay SPDT 8(3) A, 250Vac 

defrost: relay SPDT 8(3) A, 250Vac 
 fans: relay SPST 8(3) A, 250Vac 
Other output: Alarm buzzer 
Kind of action: 1B.; Pollution grade: normal; Software class: A. 
Data storing: on the non-volatile memory (EEPROM). 
Operating temperature: 0÷60 °C. 
Storage temperature: -25÷60 °C.  
Relative humidity: 20

÷

85% (no condensing) 

Measuring and regulation range: -40÷110°C (-58÷230°F) 
Resolution: 0,1 °C or 1°C or 1 °F (selectable). 
Accuracy (ambient temp. 25°C): range -40÷50°C (-40÷122°F):  ±0,5 °C ±1 digit 
 

15.

 

WIRING CONNECTIONS 

 

N.C.

Line

8(3)A250V

~

8(3)

A

8(

3)A

Max
16A

Comp1

Def

Fan

R

oom

1

1

2

3

4

5

Co

nf

ig.

2

Co

nfi

g.

1

N.C.

8(3)A

7

8

9

Line

C omp2

Ho

t K

ey

13 14 15 1 6 17 18 19

20 21

22 23

Supply

12V

=

De

f.

Ro

om

2

 

16.

 

DEFAULT SETTING VALUES 

Label  Nome 

Range 

Default  level 

 REGULATION 

 

 

 

Set1 

Set point 1 

LS1÷US1 

-5 

Pr1 

Set2 

Set point 2 

LS2÷US2 

Pr1 

Hy1 

Differential 1 

0,1÷25,5 °C / 1÷45°F 

2.0 

Pr1 

Hy2 

Differential 2 

0,1÷25,5 °C / 1÷45°F 

2.0 

Pr1 

 

REGULATION – SECTION 1 

 

 

 

LS1 

Minimum set point1 limit 

 -50,0°C÷SET1 / -58°F÷SET1 

-50.0 

Pr2 

US1 

Maximum set point1 limit 

SET1 ÷ 150°C / SET1 ÷ 302°F  110 Pr2 

odS1  Outputs activation delay of sect. 1 at start up  0÷255 min. 

Pr2 

Ac1 

Anti-short cycle delay for compressor1 0÷30 

min. 

Pr1 

con1  Compressor1 ON time with faulty probe1 

0÷255 min. 

15 

Pr2 

coF1  Compressor1 OFF time with faulty probe1 

0÷255 min. 

15 

Pr2 

cH1 

Kind of action for section 1 

cL / Ht 

cL 

Pr2 

 

REGULATION – SECTION 2 

 

 

 

LS2 

Minimum set point2 limit 

 -50,0°C÷SET2 / -58°F÷SET2 

-50.0 

Pr2 

US2 

Maximum set point2 limit 

SET2 ÷ 150°C / SET2 ÷ 302°F  110 Pr2 

odS2  Outputs activation delay of sect. 2 at start up  0÷255 min. 

Pr2 

Ac2 

Anti-short cycle delay for compressor2 0÷30 

min. 

Pr1 

con2  Compressor2 ON time with faulty probe2 

0÷255 min. 

15 

Pr2 

coF2  Compressor2 OFF time with faulty probe2 

0÷255 min. 

15 

Pr2 

cH2 

Kind of action for section 2 

cL / Ht 

cL 

Pr2 

 DISPLAY 

 

 

 

cF 

Temperature measurement unit 

°C / °F 

°C 

Pr2 

rES 

Resolution (for °C 

in ÷ de 

dE 

Pr1 

Lod1  Bottom display visualization 

P1 ÷ P4 

P1 

Pr2 

Lod2  Upper display visualization 

P1 ÷ P4 

P2 

Pr2 

 DEFROST 

 

 

 

dFS 

Relation between defrosts 

ind; StS; Sti, SE  

ind 

Pr2 

tdF1 

Kind of defrost section 1 

rE, in  

rE 

Pr2 

EdF1  Defrost mode, section 1 

In, Sd,RTC 

in 

Pr2 

SdF1  Set point  for  Smart Defrost section 1 

-30 ÷ +30°C / -22÷+86°F 

Pr2 

dtE1 

End defrost temperature section 1 

-50,0÷110°C/ -58÷230°F 

6.0 

Pr2 

idF1 

Interval between defrosts, section 1 

1÷120ore 

Pr1 

MdF1  Maximum duration of defrost, section 1 

0÷255 min. 

20 

Pr1 

tPF1 

Pre-defrost compressor on time 

0÷30 min. 

Pr2 

Fdt1 

Dripping time section 1. 1 

0÷60 min. 

Pr2 

dPo1  Defrost at power on section . 1 

n ÷ y 

Pr2 

EdF2  Defrost mode, section 2: 

In, Sd, RTC 

in 

Pr2 

idF2 

Interval between defrosts, section 2 

1÷120ore 

Pr1 

MdF2  (Maximum) duration of defrost, section 2 

0÷255 min. 

20 

Pr1 

dFd 

Display during defrost 

rt, it, SEt, dEF, dEG 

it 

Pr2 

dAd 

Defrost display time out 

0÷255 min. 

20 

Pr2 

dSd 

Defrost delay 

0÷255 min. 

Pr2 

 FANS 

 

 

 

FnC1  Fans operating mode, section 1 

C-n, C-y, O-n, O-y  

O-n 

Pr2 

Fnd1  Fans delay after defrost, section 1 

0÷255 min. 

10 

Pr2 

FSt1 

Fans stop temperature, section 1 

-50,0÷110°C/ -58÷230°F 

2.0 

Pr2 

FAP1  Probe for fans 

P1÷P3 

P3 

Pr2 

Label  Nome 

Range 

Default  level 

 ALARM 

 

 

 

ALc1  Temperature alarms configuration, section 1  rE / Ab 

Ab 

Pr2 

ALu1  Maximum alarm, section 1 

-50,0÷150°C/ -58÷302°F 

110 

Pr1 

ALL1  Minimum alarm, section 1 

-50,0÷150°C/ -58÷302°F 

-50.0 

Pr1 

ALd1  Temperature alarm delay, section 1 

0÷255 min. 

15 

Pr2 

dAo1  Delay of temp. alarm at start-up, section 1 

0 ÷ 23h 50 min. 

1.3 

Pr2 

ALc2  Temp. alarms configuration, section 2 

re ÷ Ab 

Ab 

Pr2 

ALu2  Maximum alarm, section 2 

-50,0÷150°C/ -58÷302°F 

110 

Pr1 

ALL2  Minimum alarm, section 2 

-50,0÷150°C/ -58÷302°F 

-50.0 

Pr1 

ALd2  Temperature alarm delay, section 2 

0÷255 min. 

15 

Pr2 

dAo2  Delay of temp. alarm at start-up, section 2 

0 ÷ 23h 50 min. 

1.3 

Pr2 

AFH 

Temperature alarm and fan differential 

0,1÷25,5 °C / 1÷45°F 

1.0 

Pr2 

EdA 

Alarm delay at the end of defrost 

0÷255 min. 

20 

Pr2 

dot 

Delay of temp. alarm after closing the door 

0÷255 min. 

20 

Pr2 

doA 

Open door alarm delay 

0÷254 min., nu 

15 

Pr2 

Pbc 

Kind of probe 

PTC/ntc 

ntc 

Pr2 

 ANALOGUE 

INPUTS 

 

 

 

oFS1  Thermostat1 probe calibration 

-12,0÷12,0°C / -21÷21°F 

0.0 

Pr2 

oFS2  Thermostat2 probe calibration 

-12,0÷12,0°C / -21÷21°F 

0.0 

Pr2 

oFS3  Evaporator probe calibration 

-12,0÷12,0°C / -21÷21°F 

0.0 

Pr2 

P2P 

Thermostat2 probe presence 

n / y 

Y Pr2 

P3P 

Evaporator probe presence 

n ÷ y 

Pr2 

 DIGITAL 

INPUTS 

 

 

 

i1P 

Digital input 1 polarity 

cL÷OP 

cL 

Pr2 

i1F 

Digital input 1 operating mode 

MP1; MP2, MP; EA1; EA2; 
EAL; bA1; bA2; , bAL; dF1; 
dF2; dEF;  oF1; oF2; oFF; ES  

MP1 Pr2 

i2P 

Digital input 2 polarity 

cL÷OP 

cL 

Pr2 

i2F 

Digital input 2 operating mode 

MP1; MP2, MP; EA1; EA2; 
EAL; bA1; bA2; , bAL; dF1; 
dF2; dEF;  oF1; oF2; oFF; ES  

MP2 Pr2 

odc1  Comp. and fan status when open door, sect 

no, Fan, CPr, F_C 

FAn Pr2 

rrd1 

Outputs restart after door open alarm, sect. 1  n, y 

Pr2 

did1  Time interval delay for digital input alarm, 

sect. 1 

0÷255 min. 

15 Pr2 

odc2  Comp. status when open door, section 2: 

no, Fan, CPr, F_C 

no 

Pr2 

rrd2 

Outputs restart after door open alarm, sect. 2  n, y 

Pr2 

did2  Time interval delay for digital input alarm, 

sect. 2 

0÷255 min. 

5 Pr2 

 OTHER 

 

 

 

HES1  Temp. increase during the Energy Saving 

cycle, sect. 1 

-30÷30°C / -54÷54°F 

Pr2 

HES2  Temp. increase during the Energy Saving 

cycle, section 2 

-30÷30°C / -54÷54°F 

Pr2 

Adr1 

RS485 serial address, section 1   

1÷247  

Pr2 

Adr2 

RS485 serial address, section 2 

1÷247  

Pr2 

dP1 

Thermostat 1 probe  value 

- - - 

- - - 

Pr1 

dP2 

Thermostat 2 probe value 

- - - 

- - - 

Pr1 

dP3 

Evaporator probe value 

- - - 

- - - 

Pr1 

onF 

Stand-by function 

y, n 

- - - 

Pr2 

rEL 

Release software 

--- 

- - - 

Pr2 

Ptb 

Parameter  table 

- - - 

- - - 

Pr2 

Pr2  

Access to the protected parameter list 

 

- - - 

Pr1 

 
 
 
 
 

Dixell S.p.A. 
Via dell’Industria, 27 - 32010 Z.I Pieve d’Alpago (BL) ITALY  
tel. +39 - 0437 - 98 33 - fax +39 - 0437 - 98 93 13 –  
E-mail:[email protected]  -  

http://www.dixell.com

 

Отзывы: