background image

3

KI-OM-523 R2

Chapter 1

1.3.2 FLUID 

SYSTEM

The MHE-02 may function with either salt water or fresh water as the heating medium. The
unit is provided with two inlets for fluid, one for fresh water and one for sea water. The fresh
water line is typically used for flushing the system after use. The freshwater line is fitted with
a check valve to prevent salt water contamination of the fresh water supply. The unit uses
small inexpensive immersion heater elements mounted in the flange plate of the stainless
steel heater tank to heat the fluid. The flow rate of the fluid through the heating tank is
governed by the action of the bypass valve.

The flow rate of fluid from the heater tank to the divers is determined by the motor speed and
the ratio of the pulley set used to couple the motor to the pump. The pump is a positive
displacement pump and is designed and supplied with a pulley arrangement to provide a
flow rate of 

30 litres/min

.

The fluid to be heated enters the unit at the assigned inlet and flows through a manifold and
a quarter-turn hand valve. The manifold is equipped with analogue temperature and
pressure gauges to provide operator feedback on the fluid supply. The fluid is then piped to
two separate inlet filters. The two filters may be isolated using hand valves on the inlet and
outlet of each filter. Only one filter should be used under normal operation with the other on
standby and ready to be put into operation. These filters clean input water of particulate
matter down to 50µm in order to protect the piston pump and umbilical coupling from being
damaged and prevent clogging of the heating water tubes in the diver suits. The inlet filters
are each fitted with pressure gauges in order to monitor pressure drop across the filter and
indicate the condition of the filter cartridge. A pressure regulating valve fitted after the filter

IMPORTANT

The calculated required temperature rise may be indicated on the heater bank
selection schedule as a maximum for one configuration and a minimum on the
subsequent selection of heater banks. In this case practical application will dictate
which configuration should be used. The higher capacity configuration is usually
used to allow for better control.

If the bypass dump valve remains fully open during normal operation, indicating
heating over-capacity then the lower kW heater configuration should be used to
improve control and unit performance.

If the bypass valve remains fully closed during normal operation, indicating heating
under-capacity or a possible heater bank fault then a higher kW configuration
should be used to improve control.

IMPORTANT

Fluid supply to the unit by the vessel must be maintained above 30 litres/min at 3
bar for correct operation.

Содержание MHE-02

Страница 1: ...INSTALLATION OPERATING AND MAINTENANCE MANUAL for the Mini Water Heater Electric Model MHE 02 440 VAC Supply x 24 VDC Controls Document No KI OM 523 Legacy No 05984 805 Part No KI40026AA...

Страница 2: ...Intentionally Blank...

Страница 3: ...AC Supply x 24 VDC Controls REV DATE BY CHECK APP COMMENTS 0 31 03 2010 R Carli N Maske R Faustmann First Issue 1 11 06 2010 R Carli N Maske R Faustmann Update as per ECN CT 00276 2 26 10 2012 V Garzo...

Страница 4: ...ii Approval Sheet KI OM 523 R2 Intentionally Blank...

Страница 5: ...5 1 3 4 Electrical System Detail Control Logic and Component Identification 5 1 3 5 Heater System and Heater Selection 6 1 3 6 Control System 7 CHAPTER 2 INITIAL SET UP 11 2 1 Installation 11 2 1 1 Ge...

Страница 6: ...RECOMMENDED SPARE PARTS LIST ACQUISITION FORM 39 B 1 Recommended Spare Parts List Spares Kit KI40026AA KIT 39 B 2 Recommended Spare Parts Not in Spares Kit KI040026AA KIT 41 APPENDIX C SPARES ACQUISI...

Страница 7: ...KI OM 523 FILENAME AND PATH EQUIPMENT TYPE Mini Water Heater Electric MHE 02 440V x 24V EQUIPMENT SERIAL NO CUSTOMER VESSEL LOCATION IF KNOWN DATE OF ISSUE IMPORTANT Please quote the above informatio...

Страница 8: ...vi Data Sheet KI OM 523 R2 Intentionally Blank...

Страница 9: ...document Divex makes no guarantees therefore Misuse of the equipment described in this manual could result in injury It is the responsibility of the user to ensure that the equipment is used and maint...

Страница 10: ...viii Disclaimer KI OM 523 R2 Intentionally Blank...

Страница 11: ...formation IV CONFIDENTIAL INFORMATION This document is confidential and is the property of Divex It may not be distributed to persons or organizations other than the intended recipient without the pri...

Страница 12: ...x Confidential Information KI OM 523 R2 Intentionally Blank...

Страница 13: ...y transportation on site accommodation and subsistence expenses Divex may dispatch personnel to perform on site repairs The product specification and warranty terms are subject to alteration without p...

Страница 14: ...xii Warranty KI OM 523 R2 Intentionally Blank...

Страница 15: ...ph of Temperature Loss vs Umbilical Length 18 Fig 3 2 General Arrangement 20 Fig A 1 MHE 02 General Arrangement Isometric View 35 Fig A 2 MHE 02 General Arrangement Side View 36 Fig A 3 MHE 02 General...

Страница 16: ...xiv List of Tables and Figures KI OM 523 R2 Intentionally Blank...

Страница 17: ...SCRIPTION The MHE 02 assembly Includes a motor pump heater tank pipework and a control panel These components are mounted into a robust stainless steel frame The system requires a constant supply of s...

Страница 18: ...ired temperature rise through the unit would be 36 C The heater selection table shown in Table 3 1 indicates that heater banks 1 2 and 3 should be used for the required temperature rise through the un...

Страница 19: ...ing hand valves on the inlet and outlet of each filter Only one filter should be used under normal operation with the other on standby and ready to be put into operation These filters clean input wate...

Страница 20: ...e same way as the automatic control valve and is provided to control outlet temperature if automatic control is inactive The pump supply is directly coupled to the level control tank The pump is a pos...

Страница 21: ...LOGIC AND COMPONENT IDENTIFICATION The main isolator located in the electrical panel is used to switch the main power of the unit on and off As detailed in the heater power circuit in APPENDIX D power...

Страница 22: ...equential switching of the banks reducing the instantaneous load on the supply As heater banks have separate control circuits and protection the failure of any single bank of heaters will not effect t...

Страница 23: ...he amount of fluid dumped is controlled by an electronic controller that operates the actuator on the control valve The amount to which the valve is opened is determined by the controller based on fee...

Страница 24: ...eater Bank On L2 L4 LED indication of heater bank power on Supply to heater contactor coil Run Light White Control Power On L5 LED indicating 24 VDC power to control circuit Fault Light Red Pump Trip...

Страница 25: ...ontact of the float switch This arrangement is used to reduce nuisance faults attributed to level switch vibration or bouncing The normally open contact R2 1 is used in the safety circuit to remove po...

Страница 26: ...latched with a twist release Switch Fault Reset S6 The fault rest switch unlatches the over temperature and low level fault interlock circuits and allows normal function Switch Float FS The float swit...

Страница 27: ...lative 3 4 NPT penetrator of the unit Flexible hoses with suitable connections may also be used to facilitate the integration of the unit into an installation The maximum acceptable water inlet pressu...

Страница 28: ...m should be fitted to the bottom right hand side of the stainless steel electrical enclosure The mains power cable should be installed through a suitable gland and correctly grounded to the armour Mai...

Страница 29: ...n the heater tank 7 To complete priming shut the vent valve and supply valve s 2 2 2 START UP AND FUNCTION CHECK After installation is complete the MHE 02 must be thoroughly checked prior to being put...

Страница 30: ...roller display indicates the Measured Value PV Set Value SV and run indication for the Auto tuning AT Output 1 and 2 OUT1 OUT2 and Alarm 1 and 2 ALM1 ALM2 The display is used during setting to show pa...

Страница 31: ...e Table 3 1 mounted on the panel door to determine which heater banks should be used to achieve calculated temperature rise Switch on the required heater bank switches sequentially Refer to trouble sh...

Страница 32: ...selection and supplies it will deliver water heated to within 1 C of the controller set point Confirm that the unit controls the process as specified CAUTION SYSTEM FLUSHING When the system is not in...

Страница 33: ...e determining this capacity Approximate length of umbilical in water LU Approximate operating temperature of fluid desired at bottom Tb Inlet water temperature Tin Step 1 Determine total outlet temper...

Страница 34: ...d To determine the required temperature rise Trise through the unit subtract the inlet temperature Tin from the required total outlet temperature calculated in Step 1 Step 3 Heater bank selection Afte...

Страница 35: ...0 5 0 9 13 5 5 10 9 18 27 0 10 15 18 27 40 5 15 22 27 39 54 0 22 29 39 51 67 5 29 35 51 62 81 0 35 42 62 74 94 5 IMPORTANT The required temperature rise shown in Table 3 1 indicates the differential b...

Страница 36: ...d switches for heater bank selection The MHE 02 is also equipped with several analogue gauges displaying fluid temperature and pressure throughout the system The layout of the operator interface is sh...

Страница 37: ...n optimum performance 3 Check inlet water temperature and determine required temperature settings See Section 3 1 4 Press the pump start button The pump should start and no the fault indicator lights...

Страница 38: ...uate flushing of the system pipe work with fresh water 5 Shut fresh water valve off Open the drain valve and tank vent valve and allow water to drain from the system IMPORTANT During the flushing proc...

Страница 39: ...rs The inlet water filter elements should be checked following the first few hours of operation in a new installation and after long periods spent out of service Under normal working conditions the fi...

Страница 40: ...he CAT pump on the MHE 02 unit should be carried out by an approved CAT service agent or Divex regional office Filter Inspection The most common cause of low pump pressure is damage due to foreign mat...

Страница 41: ...r 7 to 155 bar Inlet Pressure Range 1 4 to 4 bar 1 4 to 4 bar Speed Maximum Allowable 767 rev min 1150 rev min Max Maximum Fluid Temperature 71 C 71 C Crankcase Capacity 1 26 ltr 1 26 ltr Inlet Ports...

Страница 42: ...26 Chapter 4 KI OM 523 R2 Intentionally Blank...

Страница 43: ...f valve check for worn and dirty valve seats Replace worn parts Inlet filter clogged or improperly size Clean Use 50 micron filter element Check more frequently Worn packing Abrasives in pumped fluid...

Страница 44: ...seals Oil leaking at the rear portion of the crankcase Damaged or improperly installed oil gauge or crankcase rear cover o ring and drain plug o ring Replace oil gauge or cover o ring and drain plug...

Страница 45: ...expected As the system s output depends upon the flow resistance if there is low resistance the pressure will be low but the flow rate will be maintained Water will not heat Circuit breakers tripped...

Страница 46: ...gulator malfunction Clean regulator and reassemble If unit will not regulate pressure on pump to between 2 5 and 4 bar replace regulator EMERGENCY CORRECTIVE ACTION Bypassing the regulator will allow...

Страница 47: ...justment Readjust over temperature controls whichever one is turning the system off if temperature of water is low Faulty over temperature switch Determine which over temperature switch is open circui...

Страница 48: ...ghts are on If any fault lights are on remedy fault Example low water Water to system shut off and float switch will open thus keeping system off Main power switch not turned on Turn switch on Control...

Страница 49: ...out fault light Replace Faulty fault relays R1 and R2 Replace No 24 VDC control power Control transformer faulty Check output of power supply If it is not 24 V on the feed with 380 V on the supply re...

Страница 50: ...34 Chapter 5 KI OM 523 R2 Intentionally Blank...

Страница 51: ...2 HP Hose Assembly DO 06035 3 Ball Valve NPT Heater Tank Bleed Valve XV500P 8 02 4 Ball Valve Brass Fresh Water Inlet Shut off Valve XV500P 12 02 5 Check Valve DO 02780 6 Sea Water In Manifold DO 059...

Страница 52: ...2 02 13 Ball Valve NPT Filter Isolation Valves XV500P 12 02 14 Filter Housing NPT With 50 Filter Element DSA No DO 04793 DO 04768 15 Motor 4kW 4 pole DO 06051 16 Accumulator CAT S S DO 02724 17 Pump C...

Страница 53: ...63BB02QJ2A 23 Sea Water Inlet Connection NPT 24 Gauge Temp 0 100 C Swivel Brkt Inlet Water Temperature Gauge DO 06068 25 Gauge Pressure 0 100 bar Back Entry Outlet Water Pressure Gauge PBBV63BB02QJ3A...

Страница 54: ...2889 32 Emergency Stop DO 03260 DO 02891 DO 04827 33 Start Stop Switch Pump DO 04823 DO 02891 DO 02889 DO 06033 34 Heater Bank Rotary Selector Switchs 3 off DO 06031 DO 02889 DO 06032 35 Belt SPB x 12...

Страница 55: ...lve Pressure Regulator 1 DO 02723 Item 18 Fig A 2 Valve 2 Way Proportional Actuated NPT 1 DO 02788 Item 19 Fig A 2 Gauge Temp 0 100 CDial Every Angle 1 DO 06068 Item 21 24 Fig A 2 Gauge Pressure 0 10...

Страница 56: ...02304 Valve Globe NPT Brass 1 DO 03326 Oil Divex CAT Pump Lubeb litres 0 5 DO 03764 Circuit Breaker Miniature 50A 6kA 3pole 2 DO 05934 Circuit Breaker Miniature 20A 6kA 3pole 2 DO 05932 Circuit Breake...

Страница 57: ...CZ121 DO 05957 Item 8 Fig A 1 Manifold MHE 2 Dump CZ121 DO 05956 Item 9 Fig A 1 Filter Housing NPT DO 04768 Item 14 Fig A 2 Actuator E Stop Latching Mushroom RED DO 03260 Item 32 Fig A 3 Legend Emerge...

Страница 58: ...42 APPENDIX B KI OM 523 R2 Intentionally Blank...

Страница 59: ...V500P 12 02 Oil Divex CAT Pump Lubeb litres DO 03764 Valve Check Brass Euro Stop DO 02780 Circuit Breaker Minia ture 50A 6kA 3pole DO 05934 Valve Pressure Reduc ing Brass DO 02359 Circuit Breaker Mini...

Страница 60: ...r Housing NPT DO 04768 Indicator LED Module White 18 30 VAC DC DO 06033 Actuator E Stop Latch ing Mushroom RED DO 03260 Switch Selector Illumi nated GRN DO 06031 Legend Emergency Stop DO 04827 Indicat...

Страница 61: ...45 KI OM 523 R2 APPENDIX D APPENDIX D WIRING DIAGRAMS...

Страница 62: ......

Страница 63: ......

Страница 64: ......

Страница 65: ...46 KI OM 523 R2 APPENDIX E APPENDIX E PIPING AND FLOW SCHEMATIC...

Страница 66: ......

Страница 67: ...47 KI OM 523 R2 APPENDIX F APPENDIX F RKC CB100 DIGITAL CONTROLLER MANUAL...

Страница 68: ...ntenance is required for safe and proper operation of this instrument Some components have a limited service life or characteristics that change over time Every effort has been made to ensure accuracy...

Страница 69: ...a case loosen the screw once and tighten it again until the instrument is firmly fixed 6 The other mounting bracket should be installed in the same way as described in 3 to 5 When the instrument is m...

Страница 70: ...ire of 0 25 to 1 65 mm2 Make sure that during field wiring parts of conductors can not come into contact with adjacent conductive parts 3 2 Terminal Configuration Alarm output Power supply Control out...

Страница 71: ...0 Voltage 0 to 5 V DC 1 to 5 V DC 0 to 10 V DC Z 1010 Current 0 to 20 mA DC 4 to 20 mA DC Sampling cycle 0 5 seconds Input range Refer to Input range table Control method PID control ON OFF P PI or PD...

Страница 72: ...Input type symbol Input range high Input range low Automatically Power ON PV SV Display Mode The controller will display the Measured value PV and the Set value SV The controller can be switched to RU...

Страница 73: ...or PID control is performed Heat Cool PID action Proportional band setting on the heat side ON OFF action differential gap TC RTD inputs 2 0 2 C F Voltage Current inputs 0 2 of Input span TC RTD input...

Страница 74: ...should be lengthened If setting time is not correct the LBA will malfunction by turning on or off at inappropriate times or not turning on at all 3 LBA deadband function The LBA may malfunction due t...

Страница 75: ...y returns to PID control Requirements for AT cancellation The Autotuning is canceled if any of the following conditions exist When the Set value SV is changed When the PV bias value is changed When th...

Страница 76: ...limiter high Refer to P 11 0001 SLL Setting limiter low Refer to P 11 PGdP Decimal point position Refer to P 11 7 2 Exit Initialization Mode When any parameter setting is changed in the Initializatio...

Страница 77: ...function is not provided with the instrument when shipped from the factory no alarm output is available by changing SL4 and or SL5 SL4 is set to 0000 in the following cases When the instrument does no...

Страница 78: ...C 0 to SLH C SLL to 3308 F 0 to SLH F TC E SLL to 1000 C 0 to SLH C SLL to 1832 F 0 to SLH F N SLL to 1300 C 0 to SLH C SLL to 2372 F 0 to SLH F T SLL to 400 0 C 199 9 to SLH C SLL to 752 0 F 199 9 t...

Страница 79: ...iring take the following steps Apply pressure very carefully when removing internal assembly to avoid damage to the frame To conform to IEC61010 1 requirements for protection from electric shock the i...

Страница 80: ...48 KI OM 523 R2 APPENDIX G APPENDIX G BELIMO CONTROL VALVE MANUAL...

Страница 81: ......

Страница 82: ......

Страница 83: ......

Страница 84: ......

Страница 85: ......

Страница 86: ......

Страница 87: ...49 KI OM 523 R2 APPENDIX H APPENDIX H WATER PRESSURE REDUCING VALVE...

Страница 88: ...I...

Страница 89: ...bar bar bar bar...

Страница 90: ......

Страница 91: ...Nominal flow rates...

Страница 92: ......

Страница 93: ......

Страница 94: ...50 KI OM 523 R2 APPENDIX I APPENDIX I CAT TRIPLEX PUMP MANUAL MODEL 1050...

Страница 95: ......

Страница 96: ......

Страница 97: ......

Страница 98: ......

Страница 99: ......

Страница 100: ......

Страница 101: ......

Страница 102: ......

Страница 103: ......

Страница 104: ......

Страница 105: ......

Страница 106: ......

Страница 107: ...51 KI OM 523 R2 APPENDIX J APPENDIX J PULSATION DAMPENER...

Страница 108: ......

Страница 109: ......

Страница 110: ...52 KI OM 523 R2 APPENDIX K APPENDIX K PRESSURE REGULATOR...

Страница 111: ......

Страница 112: ......

Страница 113: ......

Страница 114: ......

Страница 115: ...53 KI OM 523 R2 APPENDIX L APPENDIX L FLOAT SWITCH...

Страница 116: ......

Страница 117: ......

Страница 118: ......

Страница 119: ......

Отзывы: