Variable Speed and Lift
ClearVue™ pump’s floatless sensor technology senses how fast water is filling the tank
and determines how hard the ClearVue™ needs to pump in a given installation, then
pumps only to that height. If there is a partial clog in the drain line, ClearVue™ figures
that out, and pumps a little harder. If the clog doesn’t clear, ClearVue™ goes into a
cleaning cycle and pulses the discharge water to try to dislodge the clog.
The variable lift in ClearVue™ assures that the pump impeller is spinning only as fast as
is needed to lift the condensate water to the height needed. A slower spinning impeller
means significantly less noise than conventional condensate pumps. Variable speed is a
proven, quieting feature in furnace blower motors. This electronically controlled
technology is now available in a condensate pump - ClearVue™ by DiversiTech.