TROUBLESHOOTING YOUR GFCI ELECTRICAL RECEPTACLE: 

 

PLEASE NOTE: THROUGHOUT ANY OF THE FOLLOWING STEPS (PROCEDURES); IF YOU ARE 
NOT SURE YOU CAN DO THIS JOB SAFELY, AND COMPETENTLY, REFER THIS WORK TO 
QUALIFIED PROFESSIONAL! 

 

If your unit comes equipped with a GFCI (Ground Fault Circuit Interrupter) electrical 

receptacle, and there is no power in the receptacle please consider/check the following: 

 

The extension cord (if being used) is working properly. 

 

The breaker hasn’t been tripped, or turned off. 

This type of GFCI has two testing-related buttons on it. One button is appropriately labeled “TEST”, 

and the other button is labeled “RESET”. To test the GFCI receptacle follow these steps:   

 

Plug in an appliance (lamp or night light) into the outlet.   The light should now be on.  Then 
press the “TEST” button on the GFCI.  The GFCI “RESET” button should pop out, and the 
light should go out. 

 

If the “RESET” button pops out, but the light doesn’t go out, the GFCI has been improperly 
wired.  In this case please contact a certified professional.  There may also be a problem with 
other wiring in the same circuit. 

 

If the “RESET” button doesn’t pop out, the GFCI is defective, or malfunctioned, and should 
be replaced. 

 

If the GFCI is functioning properly, and the lamp goes out, press the “RESET” button to 
restore power to the outlet. 

Conversely, if you have a GFI that has tripped (which is common) and it will not reset, you may 

have a wiring short in the circuit, a defective appliance on the circuit, or the GFI itself has become 

defective.  To test a tripping GFCI follow these steps: 

 

Remove every appliance connected to the GFCI's circuit and reset it. If it doesn't reset there 
may either be a wiring fault behind a socket outlet, or your GFCI itself has become faulty.  

 

Make sure whatever you are plugging into to the GFCI is dry and not damaged. 

 

Only plug in one item at a time. If you are plugging in a defective item it will cause the GFCI 
to trip, and that item therefore should be replaced. 

If you are still having difficulty the easiest way to troubleshoot a GFI is to obtain a GFI tester, which 

is available at most hardware stores.  It plugs into the GFI outlet, and will supply you with a 

"snapshot" of your connections, indicating wiring problems and/or the condition of the GFI.  Another 

way to troubleshoot is to simply purchase a new GFI and install it. 

Содержание FORWARD VISION II 2944K

Страница 1: ...0 South Krueger Street Suring WI 54174 diversifiedwoodcrafts com THIS DRAWING IS THE SOLE PROPERTY OF DIVERSIFIED WOOD CRAFTS IT MAY NOT BE ALTERED OR CHANGED WITHOUT PERMISSION BY APR APR DATE FORWAR...

Страница 2: ...SCREW 8X1 1 4 SQ WASHER FLAT HEAD 12 APRONS N A 0 81 THK X 4 50 W X 36 812 L 2 BRACKET APRON TO CABINET 100972 BRACKET APRON TO CABINET 2 SCREWS APRON TO CABINET 100037 SCREW 10X5 8 QUAD PNHD LUB 4 BO...

Страница 3: ...NERS 100057 CORNERS STAINLESS STEEL BASE 4 SCREWS BASE 100064 SCREW 6X 1 2 PTH SMS SS SCREW 16 ELECTRICAL BRACKET 231782 BRACKET ELEC BOX DATA OUTLET 2 SCREWS ELECTRICAL BRACKET 100649 SCREW 8X3 4 PHI...

Страница 4: ...THROUGH CLEATS POSITION REMOVABLE PANEL SO THAT BOTTOM HOLES ARE MORE THAN 4 ABOVE FLOOR ATTACH BACK PANEL TO BACK OF CABINETS WITH THE SCREWS PROVIDED INTO MOUNTING CLEATS LOCATED INSIDE ON TOP AND...

Страница 5: ...IDE OF THE CABINETS AND PLACING BOLTS THROUGH THE HOLES PROVIDED IN BACK OF CABINET INSERT WASHERS AND NUTS ON OUTSIDE TIGHTEN NUTS USING A 1 2 WRENCH OR 1 2 SOCKET AND TORQUE WRENCH TO A MINIMUM OF 1...

Страница 6: ...VE ANY WARP USING SHIMS AND C CLAMPS IF NEEDED WHEN ALIGNING THE TOP DO THIS BEFORE ADHESIVE ON EDGES SETS UP LET CURE FOR 6 12 HOURS DO NOT APPLY SILICONE ADHESIVE TO REMOVABLE PANEL STEP 8 IF YOU DO...

Страница 7: ...g in the same circuit If the RESET button doesn t pop out the GFCI is defective or malfunctioned and should be replaced If the GFCI is functioning properly and the lamp goes out press the RESET button...

Отзывы: