TROUBLESHOOTING YOUR GFCI ELECTRICAL RECEPTACLE: 

 

PLEASE NOTE: THROUGHOUT ANY OF THE FOLLOWING STEPS (PROCEDURES); IF YOU ARE 
NOT SURE YOU CAN DO THIS JOB SAFELY, AND COMPETENTLY, REFER THIS WORK TO 
QUALIFIED PROFESSIONAL! 

 

If your unit comes equipped with a GFCI (Ground Fault Circuit Interrupter) electrical 

receptacle, and there is no power in the receptacle please consider/check the following: 

 

The extension cord (if being used) is working properly. 

 

The breaker hasn’t been tripped, or turned off. 

This type of GFCI has two testing-related buttons on it. One button is appropriately labeled “TEST”, 

and the other button is labeled “RESET”. To test the GFCI receptacle follow these steps:   

 

Plug in an appliance (lamp or night light) into the outlet.   The light should now be on.  Then 
press the “TEST” button on the GFCI.  The GFCI “RESET” button should pop out, and the 
light should go out. 

 

If the “RESET” button pops out, but the light doesn’t go out, the GFCI has been improperly 
wired.  In this case please contact a certified professional.  There may also be a problem with 
other wiring in the same circuit. 

 

If the “RESET” button doesn’t pop out, the GFCI is defective, or malfunctioned, and should 
be replaced. 

 

If the GFCI is functioning properly, and the lamp goes out, press the “RESET” button to 
restore power to the outlet. 

Conversely, if you have a GFI that has tripped (which is common) and it will not reset, you may 

have a wiring short in the circuit, a defective appliance on the circuit, or the GFI itself has become 

defective.  To test a tripping GFCI follow these steps: 

 

Remove every appliance connected to the GFCI's circuit and reset it. If it doesn't reset there 
may either be a wiring fault behind a socket outlet, or your GFCI itself has become faulty.  

 

Make sure whatever you are plugging into to the GFCI is dry and not damaged. 

 

Only plug in one item at a time. If you are plugging in a defective item it will cause the GFCI 
to trip, and that item therefore should be replaced. 

If you are still having difficulty the easiest way to troubleshoot a GFI is to obtain a GFI tester, which 

is available at most hardware stores.  It plugs into the GFI outlet, and will supply you with a 

"snapshot" of your connections, indicating wiring problems and/or the condition of the GFI.  Another 

way to troubleshoot is to simply purchase a new GFI and install it. 

Содержание ADA INSTRUCTOR DESK 1214K-L-ADA Series

Страница 1: ... NUMBER 300 South Krueger Street Suring WI 54174 diversifiedwoodcrafts com THIS DRAWING IS THE SOLE PROPERTY OF DIVERSIFIED WOOD CRAFTS IT MAY NOT BE ALTERED OR CHANGED WITHOUT PERMISSION BY APR APR DATE ADA INSTRUCTOR DESK ADA INSTRUCTOR DESK ASSEMBLY INSTRUCTIONS REV A 1 OF 7 NTS EMK 11 14 16 NAME DATE DESCRIPTION ECN NO UNLESS OTHERWISE SPECIFIED DIMENSION ARE IN INCHES K DIVERSIFIED ASSEMBLY I...

Страница 2: ... SQ WASHER FLAT HEAD 12 L BRACKET 100355 BRACKET RAIL 1 25X1 25X4 25 2 SCREWS L BRACKET 100649 SCREW 8X3 4 PHIL TRUSS HEAD SMS 8 SILICONE 100711 SILICONE SEALANT CLEAR 1 RUBBER BASE MOLDING 100283 RUBBER BASE MOLDING SOLD BY FOOT 20 STAINLESS STEEL CORNERS 100057 CORNER STAINLESS STEEL BASE 10 SCREWS BASE 100064 SCREW 6X1 2 PTH SMS SS SCREW 40 ELECTRICAL BOX 100033 ELECTRICAL BOX 3 00X2X2 5 DEEP 1...

Страница 3: ...NTS REV A 3 OF 7 NTS EMK 11 14 16 NAME DATE DESCRIPTION ECN NO UNLESS OTHERWISE SPECIFIED DIMENSION ARE IN INCHES ASSEMBLY COMPONENTS ITEMS INCLUDED PART PART DESCRIPTION QTY ROD SOCKET 206505 ROD SOCKET ASSY SOCKET WASHER NUT 2 CROSSBAR 100005 ROD CROSSBAR 3 4 DIA X18 L 1 UPRIGHT 100004 ROD UPRIGHT 3 4 DIA X36 L 2 CLAMP 100002 ROD CLAMP 3 4 X 3 4 ASSY 2 NOTE 1 TOPS ARE EITHER PHENOLIC OR EPOXY 2 ...

Страница 4: ...ATTACH TO FLOOR STEP 2 WITH HELP FROM ANOTHER PERSON ATTACH BACK PANEL TO BACK OF CABINETS WITH THE SCREWS PROVIDED INTO MOUNTING CLEATS LOCATED INSIDE ON TOP AND BOTTOM OF BOTH CABINETS MAKE SURE BACK PANEL IS FLUSH WITH OUTSIDE EDGES OF CABINETS STEP 3 ATTACH L BRACKETS TO APRON WITH SCREWS PROVIDED MAKE SURE BRACKETS ARE FLUSH WITH TOP EDGE OF APRON MOUNT APRON TO SIDES OF BOTH CABINETS IN DESI...

Страница 5: ... SETS UP LET CURE FOR 6 12 HOURS TOP VIEW OF INSTRUCTOR S DESK SHOWN TOP VIEW OF INSTRUCTOR S DESK SHOWN STEP 5 APPLY SILICONE ADHESIVE TO THE SINK OPENING ON TOP LOWER SINK INTO OPENING WIPE OFF ANY EXCESS CAULK AND ALLOW TO SET LET CURE FOR 6 12 HOURS STEP 6 ATTACH RUBBER MOLDING TO BASE OF INSTRUCTOR S DESK USING CONTACT CEMENT AFTER MOLDING IS IN PLACE SCREW STAINLESS STEEL CORNER BRACKETS ON ...

Страница 6: ... REV A 6 OF 7 NTS EMK 11 14 16 NAME DATE DESCRIPTION ECN NO UNLESS OTHERWISE SPECIFIED DIMENSION ARE IN INCHES NOTE 1 STEP 1 INSERT TAPERED END OF THE UPRIGHT INTO ROD SOCKET ON THE TOP CROSSBAR UPRIGHT COMPLETE UNIT SHOWN STEP 2 SLIDE ROD CLAMP OVER THE UPRIGHT AND TIGHTEN IN DESIRED LOCATION USING THUMB SCREW PROVIDED ON CLAMP STEP 3 SLIDE CROSSBAR THROUGH THE CLAMP SOME ROD CLAMP ADJUSTMENTS MA...

Страница 7: ...ng in the same circuit If the RESET button doesn t pop out the GFCI is defective or malfunctioned and should be replaced If the GFCI is functioning properly and the lamp goes out press the RESET button to restore power to the outlet Conversely if you have a GFI that has tripped which is common and it will not reset you may have a wiring short in the circuit a defective appliance on the circuit or ...

Отзывы: