Operating Instructions
64419 A 99/03
page 10 - 17
i
Re-install the adjusting gear/cone in the grinder and turn it clockwise until the rotating
plate’s wings clear the grinding housing and the lower plate spins freely.
1
Place the spring over the gear cone, followed by the Aluminum backing plat and
screw. Turn the screw only 3 full turn ( you will tighten the after calibration of step
3.3.1).
j
Clean the mating surfaces free from dirt and coffee, and install the top stationary disc
and install and tighten the screws
k
Install the hopper and cover lid.
l
Plug in the grinder into the power outlet.
m
Perform basic calibration according to 3.3.1.
3.2
Maintenance
If the grinding quality is no longer of the required standard, the grinding discs must be
replaced.
The grinding discs should be inspected for wear at lest once a year.
3.3
Grinder calibration (adjustment)
Calibration of the grinder (with the adjusting knob) makes the fineness of the ground coffee
correspond with the fineness set on the scale (marked).
Calibration of the grinder must only be performed by persons familiar with the
unit after carefully reading the following instructions.
The basic calibration
according to 3.3.1
should be made:
- after replacing the grinding discs
- following inadvertent displacement of the basic
calibration
Change of scale setting as 3.3.2 should be performed:
- if the desired grinding fineness does not
correspond with the scale (adjusting knob)
- if an individual setting of the grinding fineness is
desired (customer setting)
Periodic checking of the grinding quality and grinding discs must only be
performed by competent specialists and/or service personnel.