4. Standard installation
Ref.
Description
Cable
1
Transmitter
/
2
Flashing light
2 x 1mm²
Antenna (integrated in the flashing light)
coaxial 58Ω
3
Key selector switch
4 x 0.5mm²
Digital combination wireless keypad
/
4
Actuator
4 x 1.5mm²
5
Photocells
4 x 0.5mm²
6
Control panel
3G x 1.5mm²
A
Connect the power supply to a type-approved omnipolar switch (not supplied), with a
contact opening distance of at least 3mm.
Connection to the mains must be via an independent channel, separated from the con-
nections to the command and safety devices.
1
4
6
A
3
2
5
5
4
5