- 33 -
0DT829 14/09/2011
49E
F2
F1
F3
L3 L2 L1
FUS
E
F4
U
W
V
- LK +
RP TC ON
ON
1 2 3 4 5 6
11 12 17 IN SA POWER
NIO
SO
EO
PRG
COM
EL07L
00000000000
www.ditec.it
17 14 12 11 0 0 0 1 1 2 3 4 6 8 9 20 41
1
3
9
4
LDV
LDR
20
EL07PW1
00000000000
ON
FUSES
ID
Value
Dimension
Circuit
F1 - F2 - F3
8A - 500V
10.3 x 38
Three phase line
F4
3.15A - 230V
5 x 20
Transformer
ADJUSTMENT LIMIT SWITCH
1. Activate the door by pressing the appropriate buttons, and check it moves
in the correct direction and If necessary, reverse the movement direction
by modifying the phase sequence, adjusting the line wires upstream of
the main switch.
2. Carry the curtain in the closed position.
3. By means of a screwdriver, turn the “C” cam until the relative micro-switch
is triggered.
4. Carry out the same procedure for the opening limit switch: bring the
curtain to the open door position, and adjust cam “A”.
5. Activate the automation to check the calibration and, if necessary, make
a further adjustment.