![DITEC 192C Скачать руководство пользователя страница 1](http://html1.mh-extra.com/html/ditec/192c/192c_installation-handbook_2510100001.webp)
DITEC S.p.A.
Via Mons. Banfi, 3 - 21042 Caronno Pertusella (VA) - ITALY
Tel. +39 02 963911 - Fax +39 02 9650314
www.ditec.it - [email protected]
192C
IP1836
rev. 2005-08-23
I
Manuale di installazione quadro elettronico per automazione REX
Electric board installation handbook for REX automations
Notice d’installation armoire électrique pour automatisme REX
Installationsanleitung für Türsteuerung REX
Manual de instalación del tablero eléctrico para automación REX
Manual de instalação quadro eléctrico para automação REX
GB
F
D
E
P
Fig. 1
MOT
BL
OPEN
RP
DIP
R1
RESET
27
9
8
3
2
1
1
0
TC
on
off
3 4
1 2
POWER
ALARM
+
-
+
-
~
~
24 V
BAT
ENC
-
-
+
+
Motor
L
N
230 V~
Transf.
Fuse 1A
Lock
Fuse
F10A
192C
1CELA
12 V
12 V
P1 SP P2
R1 SR R2
1
2
Rosso - Red Bianco - White
1
0
+
-
COM
N.O.
N.C.
24 V= / 0,3 A (max)
Chiusura automatica / Automatic closure; Chiude / Closing
Apre / Opening
Sicurezza di inversione / Reversal safety contact
Stop
Apertura parziale / Partial opening
MIN
MAX
R1
Spinta sugli ostacoli
Thrust on obstacles
0%
100%
TC
Tempo chiusura automatica
Automatic closure time
0 s
30 s
RP
Apertura parziale
Partial opening
5%
90%
OFF
ON
DIP1
Funzionamento blocco
Lock functioning
Non alimentato
Unpowered
Alimentato
Powered
DIP2
Senso di marcia
Movement direction
1 anta dx/2 ante
1 wing rt/2 wings
1 anta sx
1 wing left
DIP3
Funzionamento batterie
Batteries function
Antipanico
Antipanic
Continuo
Close
DIP4
Ultima manovra con
batterie scariche
Last operation with
unloaded batteries
Chiusura
Closing
Apertura
Opening