DISTELL MFM-1092 Скачать руководство пользователя страница 18

 

...the

 

art

 

of

 

distell

ing...

  

 

Fatmeter

 

User

 

Manual

 

Page

 

18

 

 

select

 

the

 

COM

 

port

 

then

 

ensure

 

that

 

the

 

meter

 

is

 

connected

 

properly

 

and

 

turned

 

on.

   

If

 

it

 

is,

 

try

 

selecting

 

a

 

different

 

COM

 

port.

 

Once

 

you

 

have

 

connected

 

the

 

meter

 

and

 

selected

 

the

 

correct

 

communication

 

port,

 

select

 

Download

 

Historical

 

Data

 

from

 

the

 

Download

 

menu.

  

The

 

DMS

 

will

 

now

 

monitor

 

the

 

COM

 

port

 

for

 

incoming

 

data

 

from

 

the

 

meter.

 

Step

 

3:

 

Initiate

 

the

 

download

 

from

 

the

 

meter

 

Once

 

the

 

DMS

 

is

 

ready

 

and

 

waiting

 

for

 

data,

 

the

 

meter

 

needs

 

to

 

be

 

told

 

to

 

begin

 

the

 

download.

 

Find

 

the

 

‘Download’

 

option

 

in

 

the

 

choices

 

menu

 

(see

 

Menu

 

structure’).

  

At

 

the

 

‘Standard

 

D/L’

 

option,

 

press

 

the

 

Read

 

/

 

Yes

 

button

 

then

 

look

 

for

 

the

 

data

 

arriving

 

at

 

the

 

DMS.

 

If

 

no

 

data

 

is

 

seen

 

at

 

the

 

DMS

 

then

 

you

 

may

 

have

 

selected

 

the

 

wrong

 

COM

 

port.

  

Go

 

back

 

to

 

step

 

2

 

and

 

try

 

an

 

alternative

 

port.

 

Once

 

the

 

data

 

has

 

been

 

safely

 

downloaded

 

then

 

you

 

can,

 

if

 

you

 

wish,

 

erase

 

the

 

data

 

from

 

the

 

meter.

  

You

 

can,

 

alternatively,

 

allow

 

data

 

to

 

build

 

up

 

in

 

the

 

meter

 

up

 

to

 

the

 

maximum

 

1000

 

readings.

  

If

 

you

 

wish

 

to

 

clear

 

the

 

data

 

from

 

the

 

meter

 

at

 

a

 

later

 

stage

 

then

 

you

 

can

 

use

 

the

 

Clear

 

option

 

from

 

the

 

Choices

 

menu.

 

 

 

When

 

the

 

data

 

has

 

been

 

successfully

 

downloaded,

 

it

 

will

 

appear

 

in

 

the

 

DMS

 

in

 

a

 

spreadsheet

 

/

 

grid

 

form.

  

With

 

the

 

data

 

in

 

the

 

DMS

 

you

 

can

 

now:

 

 

Print

 

the

 

data

 

 

Add

 

extra

 

columns

 

of

 

information

 

 

Save

 

the

 

data

 

in

 

native

 

form

 

as

 

an

 

.FMD

 

file.

 

 

Export

 

the

 

data

 

as

 

a

 

Comma

 

Separated

 

Value

 

(.CSV)

 

file

 

for

 

exporting

 

into

 

other

 

applications

 

such

 

as

 

Excel,

 

Access,

 

etc.

 

Real

 

time

 

data

 

download

  

You

 

can

 

use

 

this

 

function

 

to

 

download

 

data

 

in

 

real

 

time,

 

sample

 

by

 

sample,

 

each

 

time

 

that

 

an

 

average

 

reading

 

is

 

created

 

by

 

the

 

meter.

  

The

 

real

 

time

 

data

 

will

 

appear

 

on

 

screen

 

line

 

by

 

line

 

as

 

you

 

use

 

the

 

meter.

 

C H O I C E S   M E N U  

Y       D O W N L O A D       N  

No

 

Data

 

Standard

 

D/L

Downloading

Download

 

Complete

 

Erase?

 

Y

                

N

 

If

 

Yes

 

then

 

data

 

is

 

erased

 

from

 

the

 

meter‘s

 

memory

 

If

 

No

 

then

 

data

 

is

 

retained

 

in

 

the

 

meter‘s

 

memory

 

Содержание MFM-1092

Страница 1: ...USER MANUAL DISTELL MEAT FATMETER Model MFM 992 small sensor Model MFM 1092 large sensor DISTELL Com June 2011 Version 2 8 for use with v3 firmware...

Страница 2: ...distell ing pres part verb 1 to distell 2 to rapidly analyse fat content of food products using microwave technology...

Страница 3: ...Getting started 10 Switch on 10 Check pad test 10 Failed check pad test 10 Ready to start 11 Measuring product samples 11 Comparing the meter with laboratory analysis 11 Preparing laboratory samples...

Страница 4: ...19 Annotating the data 19 DMS data files 19 Printing data 19 Exporting data 19 Data Management Software help 19 Advanced topics 19 Hints and suggestions 20 Preparation of samples 20 Operation of the F...

Страница 5: ...he sample Using stored calibration data the instrument converts the response of the sensor to a percentage fat oil content that is shown on the meter s display The principles of the method were define...

Страница 6: ...ccuracy than the more compact MFM 992 small sensor Fatmeter The accuracy of the meters is shown below MFM 1092 Fat Oil Reading Accuracy 2 to 15 from 0 5 rising to 1 0 13 15 at 14 16 to 30 from 1 0 ris...

Страница 7: ...data to PC using cable supplied Allows the meter to run on external power Used for charging internal batteries Microstrip sensor The microstrip sensor is placed in contact with the sample product in...

Страница 8: ...k pad All scientific instruments need regular calibration In the case of the Fatmeter an annual calibration is recommended Where the meter is subject to intensive use a twice yearly calibration check...

Страница 9: ...into a USB port on your computer CD ROM The CD contains the user manuals Data Management System calibration charts and other useful information User manuals calibration charts A hard copy of the user...

Страница 10: ...g good contact on the pad s test area then verify that the value displayed on the meter is within the range shown on the pad Repeat this on the other side of the pad If the values on the meter are not...

Страница 11: ...adings especially with a coarse minced product For this reason the meter will take multiple samples and then average them to produce a final value Note that this can provide a useful measure of produc...

Страница 12: ...eter The results should be compared with consideration to the accuracy claims presented at the beginning of this user manual If the results do not compare favourably Check the Fatmeter use as follows...

Страница 13: ...ponds with the type of meat product that you wish to analyse The detail of each product calibration setting is shown on the associated calibration chart Note You can have up to 48 different calibratio...

Страница 14: ...uide and the download procedure is covered there Add Product option Using this menu provides the ability to programme the meter with additional calibrations This facility is especially useful for thos...

Страница 15: ...ntal Key menu option will be available This allows you to enter a sequence of eight numbers and letters that is specific to your meter and is used to change your rental settings e g change the rental...

Страница 16: ...after being downloaded to the Data Management System Some users however may use the meter purely for instant measurements without ever downloading the samples and in time the Fatmeter s storage capac...

Страница 17: ...ram functions are accessed using the menu and toolbar options There is a comprehensive on line help facility which is available by clicking on the Help menu option Historical data download This functi...

Страница 18: ...wnloaded then you can if you wish erase the data from the meter You can alternatively allow data to build up in the meter up to the maximum 1000 readings If you wish to clear the data from the meter a...

Страница 19: ...elete column option of the Edit menu DMS data files Like most applications the DMS can save data to a file on disk and load it back in again Data is stored in a proprietary format in files with a FMD...

Страница 20: ...ding is only stored by the meter upon release of the button Once the reading is stable be sure to release the button before removing the meter from the sample If the displayed reading takes a long tim...

Страница 21: ...idate the warranty Before calling for service Should you have reason to believe that a fault has occurred please first of all check the obvious Is the unit switched on Have the batteries been charged...

Страница 22: ...ge 22 Contact details The DISTELL MEAT FATMETER is manufactured in the UK by DISTELL COM UNIT 5 OLD LEVENSEAT FAULDHOUSE WEST LOTHIAN EH47 9AD SCOTLAND TELEPHONE 44 0 1501 770124 FAX 44 0 1501 772424...

Отзывы: