Disan MATRIX RANGE Скачать руководство пользователя страница 11

5.4 Connection to pipe network

1.  Connect with the muff and clamps included the 
 

middle side inlet in with piping network

2.  Connect with the muff and clamps included
 

the outlet with the exhaust line. 

3.  The silences (optional) can be connected
 

near the exhaust grid.  

5.5 Electrical connection 

Before plugging in the central unit make sure that the main power supply correspond to the 
voltage requirements written on the label, which referred to the data on the identification 
plate.  The manufacturer declines all responsibility for damages to persons or objects due to 
an electric system not in compliance with the regulation in force. 

•  Connect the low-voltage starting cable 
•  Plug-in the main electric cable.

1

2

3

5.3 Fixing the central unit

Inside the packaging you will find the special installation template to easy the position and 
fixing, as well as the installation wall plate. 

1. The template should be fixed on the 
wall where the central unit should be 
installed. For reference the inlet and 
outlet should be considered. 

2. Mark the drilling point through the template. 
3. Arrange the plate on the wall. 
4. Hang the central unit on the wall plate. 

5. Hang the suction unit the frame.

8

Содержание MATRIX RANGE

Страница 1: ...MATRIX RANGE User s manual...

Страница 2: ......

Страница 3: ...installation 7 5 2 Inlet reversibility 7 5 3 Fixing of central unit 9 5 4 Connection to pipe network 11 5 5 Electrical connection 12 6 Use of central unit 13 6 1 Use of accessories 13 7 Maintenance 14...

Страница 4: ......

Страница 5: ...artridge and easy collection of the dust 2 Unpacking Follow the instruction printed on the cardboard box to move the central unit to the location selected for installation Open the box remove internal...

Страница 6: ...1 Central unit 2 Metal fixing plate 3 Two rubber muffs 4 Four clamps for rubber muffs 5 Paper bag 6 User s guide and Guarantee coupon 7 Installation template Every central unit manufactured and packag...

Страница 7: ...3 Construction scheme Matrix FF Motor Disposable bag Flat filter Dust container Motor protection Cover with quick fix Matrix PT 4...

Страница 8: ...W 1 5 Motor stage 1 1 Inlet power supply Volt 230 Volt 230 IPX Protection degree IP55 IP55 Max Vacuum mbar 260 mbar 260 Max air volume m3 h 220 m3 h 190 Airwatt 32mm W 421 W 378 Filtration Paper Bag F...

Страница 9: ...s 70 x 60 cm lxh 5 2 Inlet reversibility The Matrix unit is usually delivered with inlet connection assembled on the right side of the unit When necessary it is possible to switch the central unit for...

Страница 10: ...ell as the installation wall plate 1 The template should be fixed on the wall where the central unit should be installed For reference the inlet and outlet should be considered 2 Mark the drilling poi...

Страница 11: ...st grid 5 5 Electrical connection Before plugging in the central unit make sure that the main power supply correspond to the voltage requirements written on the label which referred to the data on the...

Страница 12: ...for any harm or damage done due to misuse of the central unit 6 1 Use of accessories 1 Place the suitable ends together Into the handle into the two chrome plated extensions or into the chrome plated...

Страница 13: ...ain power and when the cleaner and other parts are chilled form the surrounding temperature This maintenance is made to keep the cleaner working properly and to extend the lifetime of the cleaner Empt...

Страница 14: ...the dust contai ner and check also the motor protection On Matrix FF check if the dust container drawer is full and the condition of the flat polyester filter 2 Safety protection The 10 Amp fuse blow...

Страница 15: ...d or not well secured The air loss in connection with a whistling noise by a closed inlet valve is caused by a not perfect sealing or screwing of the inlet with pipes Check the tightness and if needed...

Страница 16: ...of the present manual Not sending of guarantee coupon The manufacturer will replace under guarantee any parts that are found to be defective due to faulty construction All defective parts must be retu...

Страница 17: ...Certificato di garanzia Garantieschein Coupon of Guarantee Certificat de Garantie da affrancare zu frankieren to stamp d affranchir 14...

Страница 18: ...T i m b r o e f i r m a d e l v e n d i t o r e S t e m p e l u n d U n t e r s c h i e d d e s V e r k u f e r S t a m p a n d s i g n o f s e l l e r C a c h e t e t s i g n a t u r e 15...

Страница 19: ...16...

Страница 20: ...central vacuum systems...

Отзывы: