CLEANING OF THE FILTER:
Before touching the cleaner pay attention to its temperature, which due to the motor
can be high. Wait until the cleaner is cold from the surrounding temperature. For a per-
fect operation of the system, particular attention should be paid to the condition of the
fi
lter inside the vacuum unit. It must be checked and cleaned if necessary every 2 or 3
months or if a loss of power is noticed.
1. Uncouple the waste unit from the
machine
2. Rotate the
fi
nger grip anticlockwise
until the
fi
lter can be removed.
3. Extract the polyester
fi
lter and pro-
ceed to clean it using a compressor,
traditional vacuum, by a simple shak-
ing motion or with a clean water, being
careful not to damage it.
4. Check that the metal motor protec-
tion grill is not damaged or dirty.
5. Replace the
fi
lter into the machine
case an retighten the knurled nut.
6. Re-connect the container with the
machine being careful not to damage
the seal edges which would cause a
loss of suction (close both clamps to-
gether).
48