1.1 Description: 

      The Liverage’s Bluetooth Meter is mainly used for checking the signal output 
power of the optical communication equipment in fiber optic networks. It measures 
the average power of a continuous light beam which is emitted from the equipment 
or other optic sources. It measures power in 850 nm (Multimode) and 1310 nm / 
1550 nm (Singlemode) respectively.

 

 

 
      The Fiber Meter consists of a solid state InGaAs photo diode, signal power 
measurement circuitry, and a 3 Digits LED display. Users just connect a fiber cable 
between the transmission port of the equipment and the universal interface on the 
Fiber Meter or connect to other light source. The product will show the exact 
amount of the received power (in dBm). 
 
      The universal connector can be used for all the most common fiber interfaces 
such as ST / SC / FC and it is suitable to test both Singlemode and Multimode cables. 
With an optical 2.5 mm to 1.25 mm adapter, users can even test for 1.25 mm fiber 
interface.   
 
      Download the Liverage official Power Meter APP, and get the IOS support version 
>= 9.0], or [Android support version>= 5.0] mobile phone with Bluetooth could allow 
consumer to display the function of the Power Meter APP.     
 
    Power Meter App functions: Reference function

switch measurement data for 

dBm/mW

save testing results and upload to Cloud

battery of Power Meter. 

1.2 Features:   

 

Robust, handy design with LED digital readout. 

 

Easy to check Multimode 850 nm output power. 

 

Easy to check Singlemode 1310 nm / 1550 nm output power. 

 

Universal 2.5 mm to 1.25 mm adaptor for SC / ST / FC to LC or MU 

 

3 Digits resolution and Low Voltage Battery warning LED display. 

 

850 nm / 1300 nm (Multimode) and 1310 nm / 1490 nm / 1550 nm (Singlemode) 

 

Measuring power in Multimode &Singlemode 3 Digits 850 nm / 1310 nm / 1550 
nm within -40 dBm ~ +5 dBm ranges. 

 

Support APP connection with Bluetooth. 

   

Содержание 20102286

Страница 1: ...2 Taiwan TEL 886 3 5525268 FAX 886 3 5525388 http www liverage com tw E mail sales liverage com tw Page 1 of 10 2019 VER A Copyright 20116 Liverage Technology Inc reserves the right to modify specifications without prior notice Bluetooth Optical Power Meter Specification User Manual 2019 VER A Best nr 20102286 ...

Страница 2: ...r light source The product will show the exact amount of the received power in dBm The universal connector can be used for all the most common fiber interfaces such as ST SC FC and it is suitable to test both Singlemode and Multimode cables With an optical 2 5 mm to 1 25 mm adapter users can even test for 1 25 mm fiber interface Download the Liverage official Power Meter APP and get the IOS suppor...

Страница 3: ...8 1 6 16 25 1 4 398 39 0 126 27 2 0 15 31 6 3 501 38 0 158 26 2 5 14 39 8 2 631 37 0 199 25 3 2 13 50 1 1 794 36 0 251 24 4 0 12 63 0 1000 35 0 316 23 5 0 11 79 4 1 1259 34 0 398 22 6 3 10 100 2 1585 33 0 501 21 7 9 9 125 3 1995 32 0 631 20 10 8 158 4 2512 31 0 794 19 12 5 7 199 5 3162 2 Specification Wavelength Multimode 850 nm Optical Power Range Multimode 40 dBm 5 dBm Wavelength Singlemode 1310...

Страница 4: ...reet Chupei City Hsinchu County 302 Taiwan TEL 886 3 5525268 FAX 886 3 5525388 http www liverage com tw E mail sales liverage com tw Page 4 of 10 2019 VER A Copyright 20116 Liverage Technology Inc reserves the right to modify specifications without prior notice Dimension in mm ...

Страница 5: ...tw Page 5 of 10 2019 VER A Copyright 20116 Liverage Technology Inc reserves the right to modify specifications without prior notice 3 Operating Instructions Lift the Dust Cap for access to the connector Release linchpin then slide battery lid backward Open battery lid to change batteries 1 Dust Cap to prevent dirt contaminating the PD 2 Switch Modify wavelength by sliding the switch 1 2 3 4 5 1 4 ...

Страница 6: ... and insert one end of the fiber cable into the universal connector or directly insert it into an output connector of a fiber device or Power Source 4 Switch the slide switch to 850 nm position for measuring Multimode fiber or to 1310 nm 1550 nm position for measuring Singlemode fiber The LED figure shows the actual receiving input power values 5 Lo will be displayed when the actual power received...

Страница 7: ...e other than periodic battery changes Like any piece of electronic equipment this tool should be kept away from water high dampness dust electricity and environments of extreme temperature Do not drop this tool on a hard surface Modifying any of this tool s internal components can cause a malfunction and will invalidate the manufacturer s warranty CA means the Initial Calibration is proceeding Cb ...

Страница 8: ...ight to modify specifications without prior notice 2 Battery of Power Meter 3 Current optical power testing data result 4 Refresh the current maximum and minimum optical power 5 Maximum of optical power 6 Minimum of optical power ing 7 Show the saving testing data result 8 Save data 9 Switch the units with dBm or mW 10 Reference function For Insertion Loss testing data 11 Search Bluetooth device o...

Страница 9: ...Hsinchu County 302 Taiwan TEL 886 3 5525268 FAX 886 3 5525388 http www liverage com tw E mail sales liverage com tw Page 9 of 10 2019 VER A Copyright 20116 Liverage Technology Inc reserves the right to modify specifications without prior notice 13 Remove data 14 Output data to the cloud 13 14 ...

Страница 10: ...replacement of original parts which are defective in workmanship of materials All other costs are the sole responsibility of the owner This warranty does not cover any defects damage or deterioration due to misuse alteration or negligence 7 Ordering Information Part Number Product Type Wavelength nm Range dBm S2002312 A 3 Digits SM 1310 nm 1490 nm 1550 nm 5 dBm 40 dBm S2002333 A 3 Digits SM MM 850...

Отзывы: