![DirectOut Technologies PRODIGY.MP Скачать руководство пользователя страница 116](http://html1.mh-extra.com/html/directout-technologies/prodigy-mp/prodigy-mp_user-manual_2507539116.webp)
page 116 of 130
Prodigy.MP Manual - Version 2.0
CHAPTER 8: Troubleshooting and Maintenance
Troubleshooting
To identify a possible defect with the device please consult the following table.
If the fault cannot be resolved using these instructions, please contact your local
DirectOut representative or visit
support.directout.eu.
CHAPTER 8: Troubleshooting and Maintenance
Issue
Possible reason
Solution
Device doesn’t
work.
Power supply is
broken.
Check that the power supply switch
is on, that the device is connected to
the power supply and that the socket
is working. Defective fuses must be
exchanged by qualified service personal
only.
Optical port does
not work.
Optic is dirty.
Use an air supply to carefully remove any
dust.
Never use objects for cleaning.
No signal at the
output port.
Connections (input /
output) are mixed up.
Check the connections and change the
cables if necessary.
Check the routing matrix.
No signal at the
output port.
Signal cable defective.
Exchange the signal cable.
MADI signal at the
input is not stable.
Signal source is
defective
or
bad signal condition
(Jitter > 1 ns) - e.g.
due to exceeded
length or bad
screening attenuation
of signal cable.
Change the source
or
use appropriate cables.
Clicks in the
audiosignal.
Input source is not
in sync with clock
master of the box.
Check the status of input LED and check
clock setting of the connected device.
Содержание PRODIGY.MP
Страница 1: ...PRODIGY MP User s Manual Version 2 0...
Страница 6: ...page 6 of 130 Prodigy MP Manual Version 2 0 This page is left blank intentionally...
Страница 21: ...page 21 of 130 Prodigy MP Manual Version 2 0 CHAPTER 2 Legal issues facts This page is left blank intentionally...
Страница 32: ...page 32 of 130 Prodigy MP Manual Version 2 0 This page is left blank intentionally...
Страница 39: ...page 39 of 130 Prodigy MP Manual Version 2 0 This page is left blank intentionally...
Страница 41: ...page 41 of 130 Prodigy MP Manual Version 2 0 AN8 I MIC8 HD I MIC8 HD IO MIC8 LINE IO...
Страница 49: ...page 49 of 130 Prodigy MP Manual Version 2 0 This page is left blank intentionally...
Страница 83: ...page 83 of 130 Prodigy MP Manual Version 2 0 CHAPTER 6 RAV IO Discovery SAP SAP is used in Dante environments...
Страница 85: ...page 85 of 130 Prodigy MP Manual Version 2 0 CHAPTER 6 RAV IO This page is left blank intentionally...
Страница 97: ...page 97 of 130 Prodigy MP Manual Version 2 0 CHAPTER 6 RAV IO This page is left blank intentionally...
Страница 115: ...page 115 of 130 Prodigy MP Manual Version 2 0 This page is left blank intentionally...
Страница 130: ...DirectOut GmbH T 49 3727 5665 100 F 49 3727 5665 101 www directout eu Leipziger Strasse 32 09648 Mittweida Germany...