page 26 of 36
ANNA-LISA Manual - Version 1.1
CHAPTER 4: Operation
Generator
If one of the generator presets is active, the corresponding led is lit.
Pressing ‘SET ‘lets you load and activate one of the three stored confi guration
presets. The ‘GENERATOR’ led will now blink and every push of ‘SET’ jumps to the
next preset, which is activated immediately.
Code
Meaning
LED Code
Preset 0
Active input is fed to both outputs.
SET 1 OFF
SET 2 OFF
SET 3 OFF
Preset 1
1 kHz test tone with decreasing level
per channel
(-1 dBFS .. -64 dBFS)
SET 1 ON green
SET 2 OFF
SET 3 OFF
Preset 2
musical test tones at -20 dBFS
(good for debugging 2FS /4FS setups
with s/mux)
SET 1 OFF
SET 2 ON green
SET 3 OFF
Preset 3
uncorrelated pink noise on all chan-
nels
SET 1 OFF
SET 2 OFF
SET 3 ON green
Pressing ‘SELECT’ exits the generator submenu.
Parameter: GENERATOR
Values: SET 1 / SET 2 / SET 3