CHAPTER 3: Installation

Avoid damage from condensation by waiting for the device to adapt to the environ-
mental temperature. Proper operation can only be guaranteed between tempera-
tures of 5º C and 45º C and a maximum relative humidity of 80%, non-condensing. 
Ensure that the unit has suffi cient air circulation for cooling. 

Keep any packaging in order to protect the device should it need to be dispatched 
for service.

CHAPTER 3: Installation

Installing the Device

1.

  Open the packaging and check that the contents have been delivered

  complete and undamaged. 

WARNING!

2.

 Connect signal cable(s) for the MADI signals.

3.

 Turn on the power switch.

TIP!

Содержание ANNA-LISA

Страница 1: ...ANNA LISA User s Manual Version 1 1...

Страница 2: ...anteed that all product names products trademarks requisitions regulations guidelines speci cations and norms are free from trade mark rights of third parties All entries in this document have been th...

Страница 3: ...9 First Aid in case of electric shock 9 Updates 10 Conditions of Warranty 10 Intended Operation 10 Conformity Certi cates 11 Contact 12 Contents 12 Accessory 13 CHAPTER 3 Installation 14 Installing t...

Страница 4: ...page 4 of 36 ANNA LISA Manual Version 1 1 CHAPTER 5 Troubleshooting and Maintenance 31 Troubleshooting 31 Maintenance 31 CHAPTER 6 Technical Data 32 Index 33...

Страница 5: ...l or Index Directory at the end of the document to locate help on a particular topic You can access more information and latest news by visiting on the DirectOut website at www directout eu Convention...

Страница 6: ...ule 1 x coaxial BNC connectors MADI Formats 56 64 channel 48k 96k Frame Sample Rates 44 1 48 88 2 96 176 4 192 kHz 12 5 Bluetooth v2 0 EDR support for remote control via mobile devices USB Port USB 2...

Страница 7: ...nd test signal generation serve the aim of solid operating conditions in MADI environments Typical applications include ensuring stable signal connections detection of cabling issues poor signal condi...

Страница 8: ...at up Do not place the device close to heating sources e g heaters Observe the environmental conditions Do not dispose the device into fire water or other liquids Battery Safety Instructions WARNING T...

Страница 9: ...sending parts for repair First Aid in case of electric shock WARNING Do not touch the person or his her clothing before power is turned off otherwise you risk sustaining an electric shock yourself Sep...

Страница 10: ...nents that are essential for proper and intended operation of the device The date of purchase is applied for this period Consumable parts e g battery are excluded from warranty claims WARNING All clai...

Страница 11: ...ch the device to DirectOut GmbH Leipziger Str 32 09648 Mittweida Germany Only stamped parcels will be accepted WEEE Reg No DE 64879540 Radio The installed bluetooth antenna complies with the standards...

Страница 12: ...e 49 0 3727 5665 100 Fax 49 0 3727 5665 101 www directout eu Manufacturer Leine Weser Labor GmbH Brabeckstr 121 30539 Hannover Germany Contents The contents of your ANNA LISA package should include 1...

Страница 13: ...Fast Ethernet OC3 STM1 Gigabit Ethernet Gigabit Fibre Channel Bandwidth from 100 Mbit s 1 050 Gbit s Bandwidth 155 Mbit s 1 250 Gbit s Laser FP FP Receiver Type PIN PIN Connector LC LC Wavelength TX m...

Страница 14: ...45 C and a maximum relative humidity of 80 non condensing Ensure that the unit has suf cient air circulation for cooling Keep any packaging in order to protect the device should it need to be dispatc...

Страница 15: ...or red led indicates low level and requires charging the battery To charge the battery switch off the device and and connect it to an external USB power supply or USB computer port NOTE If the battery...

Страница 16: ...basic operation of the device Note that throughout this manual the abbreviation FS refers to sample rate or sample frequency So when dealing with scaling factors the following sample rates can be wri...

Страница 17: ...ng the battery Signal Connections ANNA LISA provides two MADI I Os coaxial BNC port SFP cage to connect other media carrying MADI signals e g bre single mode multi mode different wavelengths etc BNC O...

Страница 18: ...LED green indicating charge status ON charging battery OFF no charge blinking error Battery Level LED green yellow red indicating battery level while operation green charged 3 5 V yellow needs chargi...

Страница 19: ...ing device state OFF normal operation or device switched off blinking during rmware update or to indicate an error Bluetooth The device is equipped with a bluetooth antenna for remote control via mobi...

Страница 20: ...llowing pages each parameter and its corresponding values are de scribed The Menu Structure on page 21 provides a basic overview The LEDs in the collumn indicate the parameters The three LEDs in the r...

Страница 21: ...it a parameter setting Press SET to adjust selected parameter Input Select AES10 Spec SFP BNC EXT INT 44 1 INT 48 Sample Rate EXT 64ch 48k TX 56ch 48k TX 64ch 96k TX 56ch 96k TX Format PRESET 0 PRESET...

Страница 22: ...edia stream and the proper ties of the MADI data Code Meaning LED Code Signal violates one or more features AES10 requires or cannot be recog nized at all FAIL ON red CHECK OFF OK OFF MADI stream has...

Страница 23: ...nput OFF BNC I O active ON SFP I O active blinking slowly SFP module present blinking fast 5 Hz no SFP module present Sync The device can be clocked internally or by the active input signal INPUT SYNC...

Страница 24: ...e sync check of the incoming signal and generating the outgoing signal The SAMPLE RATE led will now blink and every push of SET cycles you through the settings Code Meaning LED Code external clock of...

Страница 25: ...DI with 48kFrame Pressing SET lets you con gure the number of channels and frame format for the output signal Code Meaning LED Code same as input signal display depends on input signal 64ch 48k Frame...

Страница 26: ...ctivated immediately Code Meaning LED Code Preset 0 Active input is fed to both outputs SET 1 OFF SET 2 OFF SET 3 OFF Preset 1 1 kHz test tone with decreasing level per channel 1 dBFS 64 dBFS SET 1 ON...

Страница 27: ...HIGH OFF 250 350 mV LOW ON yellow OK OFF HIGH OFF 350 550 mV LOW OFF OK ON green HIGH OFF 550 650 mV LOW OFF OK OFF HIGH ON yellow 650 mV LOW OFF OK OFF HIGH blinking red For the SFP input the RX pow...

Страница 28: ...ignal level and jitter are ok AMPL OFF OK ON green JITTER OFF check AMPLITUDE AMPL ON yellow OK OFF JITTER OFF check AMPLITUDE AMPL ON blinking red OK OFF JITTER OFF check JITTER AMPL OFF OK OFF JITTE...

Страница 29: ...green GOOD on green 2 3 ns BAD OFF FAIR ON yellow GOOD OFF 3 4 ns BAD ON red FAIR ON yellow GOOD OFF 4 ns BAD blinking red FAIR OFF GOOD OFF For the SFP input the RX power measurement of the SFP modul...

Страница 30: ...page 30 of 36 ANNA LISA Manual Version 1 1 CHAPTER 4 Operation...

Страница 31: ...a matching charging device using the USB connec tion Check led BATTERY CHARGE Optional SFP Module Optical port does not work Optic is dirty Use an air supply to carefully remove any dust Never use obj...

Страница 32: ...Conditions Operating temperature 5 C up to 45 C Relative humidity 10 80 non condensing MADI Port BNC coaxial 2 x BNC socket input output Impedance 75 0 3 V up to 0 6 V peak to peak MADI Port SFP 1 x...

Страница 33: ...1 RoHS 11 WEEE 11 Contact 12 Contents 12 Conventions 5 D Defective Parts Modules 9 E Environmental Conditions 14 F Feature Summary 6 Firmware Update 14 First Aid 9 I Intended Operation 10 M Menu Struc...

Страница 34: ...page 34 of 36 ANNA LISA Manual Version 1 1 Notes...

Страница 35: ...page 35 of 36 ANNA LISA Manual Version 1 1 Notes...

Страница 36: ...DirectOut GmbH T 49 3727 5665 100 F 49 3727 5665 101 www directout eu Leipziger Strasse 32 09648 Mittweida Germany...

Отзывы: