background image

+12V

GND

Fuse

D2D (4 pin, wht)

ESP (3 pin, blk)

ESP (4 pin, brn)

2 pin

4 pin

+12V

GND

D2D 

(4 pin, white)

2 pin

4 pin

cut loop (see table)

CPU1

NOTE: The appearance and connector/port arrangement on the 

Directed/Avital/Xpresskit system may differ to the examples shown .

SmartStart Module 

(Top view)

SmartStart Module to Xpresskit

Directed  System 

(Top view)

LED

+12V

GND

Fuse

D2D (4 pin, wht)

ESP (3 pin, blk)

ESP (4 pin, brn)

2 pin

4 pin

+12V

GND

D2D 

(4 pin, white)

2 pin

4 pin

cut loop (see table)

CPU1

NOTE: The appearance and connector/port arrangement on the 

Directed/Avital/Xpresskit system may differ to the examples shown .

SmartStart Module 

(Top view)

SmartStart Module to Xpresskit

Directed  System 

(Top view)

LED

Installation Procedure

This product is compatible with all Directed Electron-

ics Security, Remote Start and hybrid systems that are 

Bitwriter™ (3 or 4 pin) compatible: 

CAUTIONS:

 

Cable  connectors  and  their 

associated ports are the same color. Con-

necting  to  the  wrong  port  can  damage 

the unit.

DO  NOT

  connect  the  white  4-pin  D2D 

connector to brown ESP port on Directed 

systems.

DO NOT

 connect the black 3-pin ESP con-

nector to white Door Lock port on Direct-

ed systems.

The white connector cannot be connected 

to Xpresskit module except in standalone 

Datastart  applications  as  shown  below. 

For  all  ESP  systems,  connect  Xpresskit 

module to the Directed system, 

not

 to the 

SmartStart Y-adapter. 

Please read the following before proceeding 

1. 

Customer Information required:

•  Record  the  customer  information  requested 

in step 5a of this procedure. The module ID 

# is provided on a sticker which can be af-

fixed to the space provided in step 5a. 

•  Is this a new account or one being added to 

an existing account? Check box(es) in 5a.

This information is required for final verification/

activation of the VSM200/DSM200. 

2. 

Installation Points:

  

•  Install and test the security/remote start sys-

tem  first  using  the  associated  guides  and 

wiring diagram. If using an existing system, 

verify it is fully functional before installing the 

Directed SmartStart module. 

•  For  3000-series  Remote  Start  systems  with 

no supplied remote control, test the installed 

system using the functional commands in the 

SmartStart activation portal.

•  Mount the SmartStart module as high as pos-

sible in the vehicle (side with color label up). 

Mount  with  minimal  obstructions  that  can 

affect  communications  and  within  reach  of 

the main Directed system using the provided 

cables (do not extend). 

•  DO NOT connect the SmartStart module un-

til the final programming of the Remote Start 

main unit and verification of security/remote 

start system operations are completed.

3.  Install the VSM200/DSM200 using the informa-

QRNDSM200 2010-08

White

Brown*

Communication Type

Closed

Closed

2-way ESP

Closed

Open **

2-way D2D

*  This wire color may be blue on some units.
**

If a loop is cut, the module must be powered off 

and then on again to initiate this state change. 

Quick Reference 

Install Guide

VSM200/DSM200

Отзывы: