18
© 2001 Directed Electronics, Inc. Vista, CA
To exit the System Features Learn Routine, do one of the following:
■
Turn the ignition on.
■
No activity for longer than 15 seconds.
■
Press the Valet/Program switch too many times.
features menu
feature descriptions
1 ACTIVE/PASSIVE ARMING:
When active arming is selected, the system will only arm when the transmitter is
used. When set to passive arming, the system will arm automatically 30 seconds after the ignition is turned off.
At 30 seconds, the siren will chirp to indicate that the system is armed.
2 CHIRPS ON/OFF:
This feature controls the chirps that confirm the arming and disarming of the system.
3 SIREN DURATION 30/60 SECONDS:
It is possible to program the unit to sound for 30 or 60 seconds during
the triggered sequence.
4 SIREN OUTPUT:
The system can be programmed to output pulses instead of a continuous output when trig-
gered.
5 CHANNEL 2 DELAYED/LATCHED/LATCHED RESET WITH IGNITION/30-SECOND TIMED/60-SECOND TIMED/90-
SECOND TIMED:
Channel 2 can be programmed for these output configurations. The unit is set to the default
delayed output. To change the configuration, use
to toggle to the different settings.
FEATURE ONE-CHIRP
TWO-CHIRP
NUMBER
FEATURE
SETTING (DEFAULT)
SETTING
1
Arming
Active
Passive
2
Chirps
On
Off
3
Siren Duration
30 seconds
60 seconds
4
Siren Output
Constant
Pulsed
5
Channel 2
Delayed
Latched/latched, reset with ignition/30/60/90
6
Channel 3
Instant
Latched/latched, reset with ignition/30/60/90
7
Disarm Pulse Count
1
2/3/4/5