16
interior light exit delay, and you arm the system before the interior light
goes out, you may hear Bypass Notification chirps. Once the light shuts
off, however, the doors are monitored normally.
disarming diagnostics
Extra disarm chirps are the Tamper Alert. If three chirps are heard when
disarming, the system was triggered in your absence. If three chirps are
heard, the LED status indicator will indicate which zone was involved
when you turn the ignition on (see the
Table of Zones
section). The sys-
tem will retain this information in its memory. Refer to the
Multiple
Event Total Recall
section of this guide.
arm/disarm diagnostic chart
Action
Chirps
Light Flashes
Description
Arm
2
2
System armed
Arm
4
4
System armed with hood/
trunk active and bypassed
(zones 5 and 6)
Arm
2 (5 sec.) 4
2 (5 sec.) 4
System armed with door
active and bypassed (zone 4)
Arm
2 (10 sec.) 4
2 (10 sec.) 4
System armed with sensor
active and bypassed zones
1, 2, 3, and 8
Disarm
1
1
System disarmed
Disarm
3
3
System disarmed with
tamper alert