17

DIRECTHEALTHCAREGROUP.COM

EASY SOFTBACK

26. Parts List

1

57-283-EASY

Headrest for SB incl. attachment

2

58-220-1

Backrest SB

3

57-288-2

Armrest lock

4

58-245-L/R

Armrest SB (left/right), alloy detail only

5

58-209

Handrest

6

58-285-1

Seat frame SB

7

57-250-1

Plastic seat

7

56-233

Plastic seat/keyhole, green

8

58-280-L/R

Pillars complete (Left / Right)

9

58-277

Holder (footrests)

10

58-283-1-L/R

Footrest (left/right)

11

58-296-1

Footrest

12

58-281-1

Bottom frame

13

57-049-RF

Wheel with bolt - fully braked

13

57-040-RF

Wheel with bolt - directional lock and fully braked

14

58-360

Cover

15

57-793

End plug

16

58-253

Battery Pb 5,0 Ah

17

58-291

Cover control box

18

58-293

Bellows (silicone)

19

58-282

Cap (tilt actuator)

20

58-252

Tilt actuator TA16

21

58-290

Cover plate on the left

21

58-289

Cover plate right incl. holder tilt actuator

22

57-235

Cover/armrest

27. Spare Parts

Part no.

Description

58-255

Charger, universal volt

58-255-1/2/3/4

Cable to 58-255 (EU; UK; US; AUS)

58-254

Remote control for Easy

Содержание 56-270

Страница 1: ...EASY SoftBack User Manual Technical Manual Service Manual DIRECTHEALTH C ARE GR OUP COM Manual no 805 rev 1 210609 SWL 150 kg 330 lbs 56 270 56 270 CS 56 270 100 CS 56 270 CS UK 56 270 LOW CS...

Страница 2: ...11 23 Dimensions 13 24 Information on EMC 14 25 Further Information om EMC Advanced 14 26 Parts List 17 27 Spare Parts 17 28 Accessories 19 29 Table of Symbols 19 EASY is a well designed Hygiene Chair...

Страница 3: ...ights up after around 11 months operation as a reminder regarding the scheduled service that must be carried out at least once per year Information about how to reset the service indicator can be foun...

Страница 4: ...se after every folding disassembly and after any transport Check the battery status prior to and after each use It is important to never leave the user alone during the transfer Only transfer the user...

Страница 5: ...ion or at least every three months in the Off position Make sure protective covers are always put back in place after cleaning activities Always replace the Hygiene Chair s electrical components or ca...

Страница 6: ...ontal position and then to the lowest seat height Exercise caution when activating as the system safety sensors are bypassed In particular make sure the chair proceeds evenly to its minimum height to...

Страница 7: ...y get in and damage the remote control 5 Battery On Off The battery is located under a protective cover at the base of the chair The battery has On Off buttons that are reached through an opening at t...

Страница 8: ...h the one on the righthand front side features a directional lock and the other 3 are fitted with full brakes When the directional lock is activated wheels cannot be turned This is particularly useful...

Страница 9: ...juries make sure protective covers are always put back 17 Troubleshooting when the Chair is Inoperable NOTE Chair cannot be operated above 65 cm seat height if the chair is tilted forward nor can the...

Страница 10: ...eries must be removed and recycled as electrical components Ask your local recycling station for further information about how the different materials in the product metals plastics electronics should...

Страница 11: ...the pillars with detergent disinfectants commonly used in healthcare alcohol based Make sure the protective cover is installed at the bottom of each pillar Special checks at least once per year 1 Armr...

Страница 12: ...ng temperature 5 45 C 5 45 C Battery TBB6 Voltage 24 V Capacity 5 Ah Type Pb Protection class IP66W Battery charger TP9 Voltage in 100 240V 50 60 Hz Voltage 29V Control box TC14 Processor MCU 3 motors...

Страница 13: ...ntrol box 2 Actuators up down left 5 Remote control 3 Actuators up down right 6 Battery 4 Actuators tilt 7 Connects to outgoing connector on control box 7 Connected to spindle cable 7 23 Dimensions Al...

Страница 14: ...proval Avoid placing using the chair less than 0 35m from other medical equipment and or mobile phones or other transmitting equipment This is because there is then a risk that the main functions of t...

Страница 15: ...e 1 kV differential mode n a for common mode Mains power quality should be that of a typical commercial or hospital environment Voltage dips short interruptions and voltage variations on power supply...

Страница 16: ...be less than the compliance level in each frequency range b Interference may occur in the vicinity of equipment marked with the following symbol NOTE 1 At 80MHz and 800MHz the higher frequency range...

Страница 17: ...rest left right 11 58 296 1 Footrest 12 58 281 1 Bottom frame 13 57 049 RF Wheel with bolt fully braked 13 57 040 RF Wheel with bolt directional lock and fully braked 14 58 360 Cover 15 57 793 End plu...

Страница 18: ...EASY SOFTBACK 18 DIRECTHEALTHCAREGROUP COM...

Страница 19: ...232 Plug soft seat 56 234 Comfort seat back opening green Easy 56 259 L Calf rest left Easy 56 259 R Calf rest right Easy 56 260 L Footrest left Easy 56 260 R Footrest right Easy This product complie...

Страница 20: ...tan 35 SE 164 40 Kista Sweden Tel 46 0 8 557 62 200 info directhealthcaregroup com www directhealthcaregroup com Medical Device Class I The product complies with the re quirements of the Medical Devic...

Отзывы: