background image

3 OF 8

IG082119-9.0

NEON BLAZE

 24V LED Strip Light

 INSTALLATION GUIDE

NEON BLAZE

™ 

24V LED Strip Light

INSTALLATION GUIDE

INSTALLATION

TURN POWER OFF AT CIRCUIT 

BREAKER

SHOCK HAZARD!

 

May result in serious 

injury or death.

Turn power OFF at circuit breaker prior to 

installation

.

CREATE CONNECTION

PREPARE NEON BLAZE

 LED STRIP 

FOR INSTALLATION

Before cutting or attaching connectors, ensure that the 

arrows on the underside of the Strip Light point away 

from initial connection.

Skip to 3.3 if not cutting to specific length. 

If cutting to length, ensure to cut the Strip Light at 

the designated cut points only. Cutting anywhere 

else will cause damage to the Strip Light.

24V DC

24V DC

1

3

2

Blade

Strip Light

Clear Plastic Element

Insert spacer directly 

over

 LED Strip Light allowing 

each  arm  of  spacer  to  slide  next  to  first  LED.                                 

Spacer must be used to maintain warranty.

*Top bending BLAZE

 NEON LED Strip Light 

shown.

INSERT SPACER

3.1

2.1

2.2

TOP BENDING CONNECTOR

SIDE BENDING CONNECTOR

Slide blades of connector directly between LED Strip 

Light and clear plastic element, then press firmly.

INSERT CONNECTOR

3.2

-

+

-

+

-

+

-

+

Note: Failure to follow installation instructions may void warranty.

Содержание NEON BLAZE

Страница 1: ...y a qualified licensed electrician 3 Do not modify or disassemble this product beyond instructions or the warranty will be void 4 Do not use if there is any damage to the fixture or wiring Inspect periodically 5 Do not submerge Strip Light in liquids or use the product in the vicinity of standing water or other liquids 6 Do not install near areas with exposure to chlorinated water Salt water envir...

Страница 2: ...t location Recommended sealant is the DI WPSL or equivalent HANDLE PRODUCT WITH CARE DO NOT BEND LED STRIP LIGHT TO A DIAMETER LESS THAN 4 INCHES 4 in DO NOT BEND LED STRIP LIGHT ON A HORIZONTAL PLANE DO NOT COVER STRIP LIGHT WITH ANY MATERIALS DO NOT FOLD CREASE OR TWIST LED STRIP LIGHT DO NOT POWER STRIP LIGHT WHILE ATTACHED TO SPOOL OR TIGHTLY COILED TOP BENDING NEON BLAZE LED Strip Light DO NO...

Страница 3: ...if not cutting to specific length If cutting to length ensure to cut the Strip Light at the designated cut points only Cutting anywhere else will cause damage to the Strip Light 24V DC 24V DC 1 3 2 Blade Strip Light Clear Plastic Element Insert spacer directly over LED Strip Light allowing each arm of spacer to slide next to first LED Spacer must be used to maintain warranty Top bending BLAZE NEON...

Страница 4: ...ector cover together completely surrounding connection point Top bending NEON BLAZE LED Strip Light shown Top bending NEON BLAZE LED Strip Light shown Top bending NEON BLAZE LED Strip Light shown Press until cover snaps in place Press until cover snaps in place Press until cover snaps in place Apply liberal amounts of sealant in these locations Apply liberal amounts of sealant in these locations A...

Страница 5: ...ert NEON BLAZE LED Strip Light into bottom u clip Note It is recommended to use two bottom u clips for every foot of NEON BLAZE LED Strip Light 4 a Option A Bottom U Clips Option B Top U Clips b Place NEON BLAZE LED Strip Light on surface then place clear top u clip over Strip Light Note It is recommended to use two clear top u clips for every foot of NEON BLAZE LED Strip Light Screw top u clip to...

Страница 6: ... LED Strip Light may be bent up and down on the vertical axis of the Strip Light Side bending NEON BLAZE LED Strip Light may be bent Left and Right on the horizontal axis of the Strip Light 5 CONNECT TO 96 EXTENSION CABLE Top bending and side bending connector will have wet location rated plug connector female on opposite end 96 NEON BLAZE Extension cable will have wet location rated plug connecto...

Страница 7: ... are turning on off repeatedly Ensure driver is not overloaded An overloaded driver will trip the internal auto reset of driver repeatedly turning the system on off 6 Wire Gauge 10 W 42 A 20 W 83 A 30 W 1 3 A 40 W 1 7 A 50 W 2 1 A 60 W 2 5 A 70 W 2 9 A 80 W 3 3 A 100 W 4 2 A 18 AWG 134 ft 68 ft 45 ft 33 ft 27 ft 22 ft 19 ft 17 ft 14 ft 16 AWG 215 ft 109 ft 72 ft 54 ft 43 ft 36 ft 31 ft 27 ft 22 ft...

Страница 8: ...s 2 Low Voltage Driver3 Installed in Junction Box 7 V Black Input Output V Red Install appropriate wire gauge type V V LED Tape Light Fixture 8 REIGN 12 24V Dimmer4 V V L N AC Power 50 60Hz INPUT OUTPUT 1 Driver may not require a fault ground connection Refer to driver specifications for additional information 2 Install a compatible Class 2 constant voltage driver Refer to each driver specificatio...

Отзывы: