background image

5 OF 5

®

Toll Free: 877.817.6028 | Fax: 415.592.1596 | www.DiodeLED.com | [email protected]

© 2021 Elemental LED Inc. All rights reserved. Specifications are subject to change without notice.

IG050421-2.0

DMX ZONE CONTROLLER

 INSTALLATION GUIDE

TROUBLESHOOTING

For thorough troubleshooting of LED strip light and luminaires, see LED luminaire installation guides. 

LED luminaires not responding to touch 

1.  Ensure the blue indicator light is on by pressing ‘Power.’ A red indicator signifies the device is off. The blue indicator light will blink rapidly when 

pressing/holding any key on the touch pad. 

2.  Ensure the DMX decoder/luminaire is addressed properly. For example, address ‘001’ will respond to zone 1 of the controller. See ‘Setting the 

DMX Address’ for additional addressing information.

LED luminaire responding incorrectly

Ensure all wiring connections are correct. Reversing the Data + and Data - will cause lights to flicker and not respond to controller.

1.  Check power connections of all components (drivers, DMX decoders/luminaires, DMX controller).

2.  Check DMX Data connections - See 

Pinout Connection Guide

 and 

System Diagram

 for RJ45 hard-wiring connections.

3.  Check DMX decoder connections – 

See System Diagram

 for CH 1-4 connections.

Visit the online product page at www.DiodeLED.com for additional product specifications & warranty information. 

•  TUNABLE WHITE DMX512 CONTROLLER SPECIFICATION SHEET

     For full specifications.

•  VOLTAGE DROP CHARTS

   

  Use to specify appropriate wire gauge for installation. Available at the ‘Resources’ page at www.DiodeLED.com.

ADDITIONAL RESOURCES

Содержание DI-DMX-WIFI-WMDC-1ZWH

Страница 1: ...inaire See SYSTEM DIAGRAM for more information DMX luminaires can be connected directly to controller DMX Decoders are only utilized to control Non DMX type luminaires 3 If system remains unresponsive or is working improperly turn OFF main power at breaker and verify all connections 4 CONNECT COMPONENTS Only use copper wiring Reference WIRING CONNECTIONS and SYSTEM DIAGRAM further in this guide fo...

Страница 2: ... Search for TOUCHDIAL and download application WIRING CONNECTIONS INSTALLATION CONT DO NOT connect directly to 120VAC See System Diagram for a general system design MOUNTING Pop off faceplate with a flathead screwdriver Mount to a standard switchbox PAIRING CONTROLLER TO MOBILE DEVICE 1 Go to WiFi settings of mobile device 2 Connect to WiFi Network EasyLighting 3 Type in Password 0123456789 4 Open...

Страница 3: ...m White CH2 Cool White Example of DMX Addressing Display Digital Display The following diagrams tables indicate the appropriate connections for patching your own CAT5 RJ45 and XLR 3 splice cables These diagrams are for general reference and may slightly differ between different cable manufacturers 1 2 3 4 5 6 7 8 Pin No Wire Color Function 1 White Orange Data 2 Orange Data 3 White Green None 4 Blu...

Страница 4: ...W 0 5 0 9 0 9 Data IN Data OUT V V V CH1 R CH2 G CH3 B CH4 W 0 5 0 9 0 9 Data IN Data OUT G DMX Data Output Power Input AC Power 50 60Hz L N Class 2 Low Voltage Driver Installed in Junction Box G N L Input Output V V DMX Controller Installed in Wall Box CAT5 Ethernet Cable RJ45 Connections DMX Decoder DMX Decoder V V V V RJ45 Coupler RJ45 Splice Cable V V CH1 WW CH2 CW Install applicable wire gaug...

Страница 5: ...ond to zone 1 of the controller See Setting the DMX Address for additional addressing information LED luminaire responding incorrectly Ensure all wiring connections are correct Reversing the Data and Data will cause lights to flicker and not respond to controller 1 Check power connections of all components drivers DMX decoders luminaires DMX controller 2 Check DMX Data connections See Pinout Conne...

Отзывы: