  Usage limits (IEC 60974-2)

The cooling module is sized for cooling by means of water cir-
culation in the torch head in a continuous manner. As a work 
cycle, it is considered at 100%.

 Installation

WARNING: The cooling device may only be installed horizon-
tally.

The installation site for the system must be carefully chosen in 
order to ensure its satisfactory and safe use.
The user is responsible for the installation and use of the sys-
tem in accordance with the producer’s instructions contained 
in this manual.
Before installing the system the user must take into consider-
ation the potential electromagnetic problems in the work area. 
In particular, we suggest that you should avoid installing the 
system close to:

• 

Signalling, control and telephone cables.

• 

Radio and television transmitters and receivers.

• 

Computer and control and measurement instruments.

• 

Security and protection instruments.

Persons fitted with pace makers, hearing aids and similar 
equipment must consult their doctor before going near a ma-
chine in operation. The installation environment of the device 
has to be in conformance with the protection degree of the 
housing, which is equivalent to IP 23 (publication IEC 60529), 
which means that the device may be used in closed environ-
ments as well as outdoors. This system is cooled by means of 
the forced circulation of air, and must therefore be placed in 
such a way that the air may be easily sucked in and expelled 
through the apertures made in the frame.

  Usage norms

CONTROL APPARATUS (Fig. A)

Pos. 1

 

Red snap-in connector for water intake.

Pos. 2

 

Blue snap-in connector for water outlet.

Pos. 3 

Cap with microvalve for filling of the tank with coolant.

Pos. 4 

Cable for electric connection of the device to the gen-
erator cooling connector.

Pos. 5 

Level indicator for presence of coolant in the tank (the 
level of the liquid must never be inferior to the notch 
indicated).

Pos. 6 

Protection fuse.

  Electrical wiring of the welding cooling 

device and successive mechanical 
coupling

The cooling device is not designed as a stand-alone system 
and therefore it must be connected electrically, in order to op-
erate, to the welding power source, making the coupling be-
tween the 3x2 pole male connector in the cooling devise (Pos. 
4, fig. A) and the corresponding female on the welding power 
source (to ignite the female connector just remove its specific 
covering (Fig. B) located under the base of the machine) fol-
lowing the assembly instructions attached.
Prior to beginning, the operator has to assure that close at 
hand there is both the welding power source (example: DIX TIG 
1906.M HF) and the cooling device (example: DIX CM 141.M) 
and that both are working at the same supply voltage (see the 
two data panels positioned under the respective bases).
Upon final connection, even the pressure switch will be con-
nected. The pressure switch has a protective function. It does 
not allow the welding power source to emit voltage in case the 
water pressure and therefore the cooling capacity, is inferior 
to the calibration value.
Having terminated the electrical connections, complete the me-
chanical coupling by means of screws and fastening clamps.

FIG. A

FIG. B

Содержание DIX CM 141.M

Страница 1: ...DIX CM 141 M DIX CM 592 M BA 0104 Cooling modul S C H W E I S S E N W E L D I N G W E L D I N G S C H W E I S S E N S C H W E I S S E N Keep in secure area for future reference Operations manual ...

Страница 2: ...icult welding operations and consists mainly of A single phase electric pump A plastic tank A cooler A pressure monitor A fuse The cooling module is particularly compact and lightweight It is designed as part of a welding power source For other appli cations please contact your DINSE consultant Technical data The general technical data of the cooling module are summa rized in table 1 Table 1 Model...

Страница 3: ... Usage norms CONTROL APPARATUS Fig A Pos 1 Red snap in connector for water intake Pos 2 Blue snap in connector for water outlet Pos 3 Cap with microvalve for filling of the tank with coolant Pos 4 Cable for electric connection of the device to the gen erator cooling connector Pos 5 Level indicator for presence of coolant in the tank the level of the liquid must never be inferior to the notch indic...

Страница 4: ...ximately 30 seconds so that the cooling device can allow the liquid to circulate D Wait for the exit of the liquid The operation will be termi nated when the liquid exits in a constant way and without any traces of air bubbles E Upon the completion of the operation turn the welding pow er source off F After that screw the tank s cap shut and connect the weld ing power source prior to beginning ope...

Страница 5: ...cap with microvalve V Fan W Pressure switch 1 Fuse 2 Cold water outlet 3 Hot water intake for cooling in the unit 4 Grounding 5 Warning 6 Before using the equipment you should careful ly read the instructions included in this manual 7 Product suitable for free circulation in the European Community CA Power supply connector F Fuse M Electric pump W Pressure switch Bl Blue Gg Grey GV Yellow Green Mr...

Отзывы: